812511
48
Zoom out
Zoom in
Previous page
1/68
Next page
W
m
W
z
12345678 9 10 11 12
NC NO C
48
24-CONNECTIONS
• Puer thermostat
To activate this option, connect a Normally Open (N.O.) contact thermostat to points 1 and 2 of the back 9 pole terminal board.
Even with this conguration the purpose of the room probe on the stove is only to control the heating system pump controlled by the
potential free contact on terminals 7-8-9.
Connections table.
TERMINAL NO. NAME ON BOARD FUNCTION
1-2 NTC2 HIGH PUFFER PROBE - PUFFER THERMOSTAT
3-4 NTC1 ROOM PROBE - ROOM THERMOSTAT
5-6 NTC3 STORAGE TANK PROBE - STORAGE TANK THERMOSTAT-
MEDIUM PUFFER PROBE
7-8-9 AUX RELAY (Potential-free-contact -Maximum
contact voltage - 24V AC/DC)
7 - NORMALLY CLOSED
8 - NORMALLY OPEN
9 - COMMON
10-11-12 3-WAY RELAY (Mains voltage contacts) POS.10 - DHW (F)
POS.11 - COMMON (N)
POS.12 - HEATING (F)
To access terminal block W”, remove the cap as reported in part 1 of the manual (in the paragraph devoted to the removal of the back
panel). Then loosen the two screws “z” and take out terminal block W”. Perform the necessary connections and place everything back.
The NTC probes must be 10 K Ω B3435,
the thermostats must have a dry
contact.
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ SUITE Hydromatic 18 M2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ SUITE Hydromatic 18 M2 in the language / languages: English as an attachment in your email.

The manual is 9.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ SUITE Hydromatic 18 M2

MCZ SUITE Hydromatic 18 M2 Installation Guide - English - 68 pages

MCZ SUITE Hydromatic 18 M2 User Manual - German - 68 pages

MCZ SUITE Hydromatic 18 M2 Installation Guide - German - 68 pages

MCZ SUITE Hydromatic 18 M2 User Manual - Dutch - 68 pages

MCZ SUITE Hydromatic 18 M2 Installation Guide - Dutch - 76 pages

MCZ SUITE Hydromatic 18 M2 User Manual - French - 68 pages

MCZ SUITE Hydromatic 18 M2 Installation Guide - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info