1-WARNINGS AND WARRANTY CONDITIONS
INFORMATION:
• Please contact the retailer or qualied personnel for any information, problem or malfunction.
• Only use the fuel specied by the manufacturer.
• When the product is switched on for the rst time, it is normal for it to emit smoke due to the paint heating up for the rst time.
Therefore make sure the room it is installed in is well-ventilated.
• Periodically check and empty the inspectionable parts of the smoke duct (e.g. Tee tting caps)
• Have the smoke outlet system periodically checked and cleaned
• The product is not a cooking appliance.
• Always keep the cover of the fuel hopper closed.
• Store this installation and user manual with care as it must accompany the product for the duration of its useful life. If the product is
sold or transferred to another user, always ensure the manual is also handed over.
INTENDED USE
The product only works with wood pellets and must be installed inside a room.
PRODUCT PERFORMANCE CHECKS.
All our products undergo ITT TESTS carried out by a notied third party laboratory (system 3) and in accordance with Regulation (EU)
number 305/2011 “Construction products”, according to standard EN 14785:2006 for household appliances and “Machinery Directive EN
303-5 for boilers.
In the case of tests for any market surveillance or inspections by third parties, please consider the following warnings:
• To reach the declared performance levels, the product must perform an operating cycle of at least 15-20 hours beforehand.
• Set the average draught of the combustion fumes as specied in the “technical product features table
• The type of pellets used must comply with the current EN ISO 17225-2 class A1 regulation. Fir pellets are usually used for certication.
• The amount of thermal energy can vary according to the length and caloric value of the fuel. This may require some adjustments
(accessed from the user menu) to comply with the hourly consumption specied in the “technical product features” table. Using class
A1 pellets guarantees a caloric value that is likely to be close to that used in the product certication; the size of the pellet grains can
signicantly aect hourly fuel loading and consequently performance; it is therefore suggested to use pellets with a 6 mm diameter
and an average length of around 24 mm (avoid pellets that are too long or excessively crushed).
• With wood-burning appliances, the fuel must comply with the current EN ISO 17225-5 class A1 regulation. Check the correct moisture
of the fuel, as it must be within the range of 12 - 20% (it is best if the moisture is close to 12%, as is normally used in certication). As
the fuel moisture increases, dierent combustion air settings are required, which are implemented from the combustion air register,
thereby modifying the mixture of primary and secondary air
• It is important to check the operation of devices that can aect performance (for example air fans or electric safety devices) in case
of damage due to handling.
• Nominal performance has been obtained by setting the maximum ame power and room ventilation in manual mode.
Performance at reduced power was achieved at minimum ame and ventilation power (P1 and V1) in manual mode.
The other conditions correspond to intermediate ventilation and power.
• If a “verication” mode is provided in the menu, set this function during the readings to ensure that no temperature modulation
occurs due to an incorrect setting of the operating parameters.
• Lastly, strictly comply with the sampling points specied in the regulations in terms of emissions as well as temperature
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ SUITE Hydromatic 18 M2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ SUITE Hydromatic 18 M2 in the language / languages: English as an attachment in your email.

The manual is 8.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ SUITE Hydromatic 18 M2

MCZ SUITE Hydromatic 18 M2 User Manual - English - 68 pages

MCZ SUITE Hydromatic 18 M2 User Manual - German - 68 pages

MCZ SUITE Hydromatic 18 M2 Installation Guide - German - 68 pages

MCZ SUITE Hydromatic 18 M2 User Manual - Dutch - 68 pages

MCZ SUITE Hydromatic 18 M2 Installation Guide - Dutch - 76 pages

MCZ SUITE Hydromatic 18 M2 User Manual - French - 68 pages

MCZ SUITE Hydromatic 18 M2 Installation Guide - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info