PELLET STOVES Chapter 6
INSTALLATION AND USE MANUAL
page 71
Problems / Causes / Solutions Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
PROBLEM POSSIBLE CAUSES REMEDY
The smoke extraction
motor does not work.
1. No electrical supply to the stove.
2. The motor is broken.
3. Defective electronic board.
4. Control panel broken.
1. Check the supply voltage and the
protection fuse.
2. Check the motor and capacitor and
replace if necessary.
3. Replace electronic board.
4. Replace the control panel.
In the automatic
position the stove
always runs at full
power.
1. Room thermostat set to maximum.
2. Temperature sensor defective.
3. Control panel defective or broken.
1. Reset the thermostat temperature.
2. Check the operation of the sensor
and replace if necessary.
3. Check the panel and replace if
necessary.
The stove does not run 1. Lack of electricity supply.
2. Pellet sensor in lockout.
3. Fuse blown.
1. Check that the electric socket is plugged
in and that the main switch is in position
“I”.
2. Clear lockout by resetting the rear
thermostat, replace the thermostat if
it happens again.
3. Replace the fuse.