34-CLEANING
Technical Dept. - All rights reserved - Reproduction prohibited
CLEANING THE SMOKE EXPULSION SYSTEM AND GENERAL CHECKS
Clean the smoke outlet system, especially around the Tee ttings, elbows and any horizontal sections of the smoke duct.
For information on periodically cleaning the ue, contact a skilled chimney sweep.
Check the seal of the ceramic bre gaskets on the door of the stove. If necessary, order new replacement gaskets from the retailer or
contact an authorised service centre to carry out the operation.
ATTENTION:
The frequency with which the smoke outlet system is cleaned depends on the use of the stove and the type of
installation.
We recommend relying on an authorised service centre for end-of-season cleaning and maintenance, as they will
carry out all of the previously mentioned work and inspect the stove components.
When the side panel has been taken down, clean the
smoke pipe.
Remove cap “B and gasket G. Then clean pipe T, cap
B and if necessary, change gasket G”.
PERIODICAL CHECK OF THE DOOR CLOSURE
Make sure the door closure ensures correct sealing action (with the “paper sheet” test) and that when the door is closed, the closing block
(X in the gure) does not protrude from the sheet metal to which it is secured. For some products it will be necessary to disassemble the
cladding to be able to assess the anomalous protrusion of the block when the door is closed.
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ SUITE COMFORT AIR 12 UP M3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ SUITE COMFORT AIR 12 UP M3 in the language / languages: English as an attachment in your email.

The manual is 11.92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ SUITE COMFORT AIR 12 UP M3

MCZ SUITE COMFORT AIR 12 UP M3 Installation Guide - English - 64 pages

MCZ SUITE COMFORT AIR 12 UP M3 User Manual - German - 72 pages

MCZ SUITE COMFORT AIR 12 UP M3 Installation Guide - German - 64 pages

MCZ SUITE COMFORT AIR 12 UP M3 User Manual - Dutch - 72 pages

MCZ SUITE COMFORT AIR 12 UP M3 Installation Guide - Dutch - 64 pages

MCZ SUITE COMFORT AIR 12 UP M3 User Manual - French - 72 pages

MCZ SUITE COMFORT AIR 12 UP M3 Installation Guide - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info