2-INSTALLATION
In any case, ensure adequate distance to facilitate access during cleaning and extraordinary maintenance. If this is not possible, it must
still be possible to distance the product from adjacent walls/elements.
This operation must be performed by a technician qualied to disconnect the combustion product expulsion ducts and their subsequent
restoration.
For generators connected to the hydraulic system, a connection must be provided between the system itself and the product so that,
during extraordinary maintenance, carried out by a qualied technician, it is possible to move the generator by at least 50 cm from
adjacent walls without emptying the system (e.g. by using a double shut-o gate or suitable exible connection).
Air inlet
It is mandatory to provide an adequate external air inlet that supplies the combustion air required for the product to work properly. The
ow of air between the outside and the installation room can take place with a free air inlet or by channelling the air directly to the
outside3.
The free air inlet must:
be made at oor level
always be protected with an outer grille and in such a way that it cannot be obstructed by any object
have a minimum total free area of 80 cm2 (net of the grille)
The presence of other suction devices (e.g.: vmc, electric fan for stale air extraction, kitchen hood, other stoves, etc.), in the same room
could cause negative pressure in the room. In this case, with the exception of sealed installations, one must verify that, with all the
equipment on, no more than 4 Pa of negative pressure is created inside the installation room with respect to the outside. If necessary,
increase the air inlet section.
It is possible to duct the air required for combustion to the outside by connecting the external air inlet directly with the combustion air
inlet which is usually found on the back of the appliance.
The duct must comply with the following dimensions (each 90° bend is equivalent to one linear metre):
3 in the event the combustion air is ducted on unsealed products, still verify that no more than 4 Pa of negative pressure is created inside the installation room with respect to the
outside, otherwise provide for an additional air intake in the room.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ SUITE COMFORT AIR 12 M3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ SUITE COMFORT AIR 12 M3 in the language / languages: English as an attachment in your email.

The manual is 3.04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ SUITE COMFORT AIR 12 M3

MCZ SUITE COMFORT AIR 12 M3 User Manual - English - 72 pages

MCZ SUITE COMFORT AIR 12 M3 User Manual - German - 72 pages

MCZ SUITE COMFORT AIR 12 M3 Installation Guide - German - 60 pages

MCZ SUITE COMFORT AIR 12 M3 User Manual - Dutch - 72 pages

MCZ SUITE COMFORT AIR 12 M3 Installation Guide - Dutch - 60 pages

MCZ SUITE COMFORT AIR 12 M3 User Manual - French - 72 pages

MCZ SUITE COMFORT AIR 12 M3 Installation Guide - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info