The EC Declaration of Conformity, the Declaration of Performance required by EU Regulation 305/2011 and all
other product certication documents can be downloaded by scanning the QR code on this page (also found
on the product label) or by accessing the website page www.mczgroup.com/support/mcz
Having specied the above, we highlight and report that:
• This manual and technical data sheet, also available on our website, bear all of the specic indications and necessary and
essential information to choose the product, to install it correctly and to properly size the smoke expulsion system;
• the Products must be installed, controlled and serviced by a qualied operator, according to the instructions in this manual and
in compliance with the laws and installation and maintenance standards in force in individual countries, so as to provide an ecient
heating system, properly sized according to the needs of the home;
• if the Products are thermally stressed, constantly operating for several hours at high power (e.g. 3, 4 hours a day at outputs P4
or P5), we recommend more frequent cleaning and reducing the interval between routine maintenance operations according to the
operating condition of the product. We furthermore point out that these operating conditions increase the risk of premature wear of
the product, especially those parts exposed to the direct heat of the re (e.g. combustion chamber), the original condition of which
can undergo modications and deterioration which, among other things, could generate noise during operation of the unit due to
mechanical expansion.
The manufacturer will not be held liable if the above information is ignored.
11
2-INSTALLATION
Technical Dept. - All rights reserved - Reproduction prohibited
The instructions in this chapter refer explicitly to the Italian installation regulation UNI 10683. In any case,
always observe the regulations in force in the country of installation.
PELLETS
The pellet is obtained from natural dried wood sawdust (without paint). The compactness of the material is guaranteed by the lignin
contained in the wood itself, without glue or binders.
The market oers dierent types of pellets with characteristics that vary according to the wood mixtures. The most common diameter on
the market is 6 mm (although 8 mm diameter is also available) with a length, on average, between 3 and 40 mm. A good quality pellet
has a density of between 600 and 750 or more kg/cubic metres and a moisture content that accounts for 5 to 8% of its weight.
Pellets have technical advantages besides being an ecological fuel, as the wood residue is used completely, thereby achieving cleaner
combustion than that of fossil fuels.
While good-quality wood has a caloric value of 4.4 kW/kg (15% moisture, after about 18 months of seasoning), that of pellets is around
4.9 kW/kg. To ensure good combustion, the pellets must be stored in a dry place and protected from dirt. Pellets are usually supplied in 15
kg bags, therefore, storing them is very convenient.
Good quality pellets guarantee good combustion, thereby decreasing harmful emissions into the atmosphere.
The poorer the quality of the fuel, the more often the internal parts of the brazier and combustion chamber need to
be cleaned.
The main quality certications for pellets currently available on the European market guarantee that the fuel complies with class A1/
A2 according to ISO 17225-2. These certications include, for example, ENPlus, DINplus, Ö-Norm M7135, and specically assure that the
following characteristics are complied with:
• caloric value: 4.6 - 5.3 kWh/kg.
• Water content: ≤ 10% of the weight.
• Percentage of ash: max 1.2% of the weight (A1 less than 0.7%).
• Diameter: 6±1/8±1 mm.
• Length: 3-40 mm.
• Content: 100% untreated wood without the addition of binding agents.
The company recommends using certied fuel for its products (ENPlus A1, DINplus, Ö-Norm M7135).
The use of pellets that do not comply with the characteristics specied previously may compromise the operation of
your product and therefore invalidate the warranty and product liability.
15 Kg BAG OF PELLETS
12
2-INSTALLATION
FOREWORD
The heating system (generator + combustion air supply + combustion product expulsion system + any hydraulic/aeraulic
system) must be installed in compliance with the laws and regulations in force1, and carried out by a qualied technician,
who must issue a declaration of conformity of the system to the system manager and shall undertake full responsibility
for nal installation and consequent good operation of the product.
The manufacturer declines all responsibility in the event of installations that do not comply with the laws and regulations in force and
inappropriate use of the appliance.
In particular one must ensure that:
• the environment is suitable for installing the appliance (oor load-bearing capacity, presence or possibility of creating an adequate
electrical/hydrauic/aeraulic system when required, volume compatible with the appliance characteristics, etc.);
• the appliance is connected to a smoke expulsion system correctly sized according to EN 13384-1, which is resistant to soot re and
which complies with the distances prescribed by the combustible materials indicated on the plate data;
• there is a suitable combustion air ow to the appliance;
• other combustion appliances or extraction devices installed do not cause a negative pressure of more than 4 Pa in the room where
the product is installed compared to the outside (only sealed appliances are allowed a maximum of 15 Pa of negative pressure in
the room).
1 The national reference standard for the installation of domestic appliances is UNI 10683 (IT) - DTU NF 24.1 (FR) - DIN 18896 (DE) - NBN B 61-002 (BE) - Real Decreto 1027/2007
(ES)
In particular, it is recommended to strictly observe the safety distances from combustible materials to avoid serious harm
to people and to the integrity of the home.
Installation of the appliance must ensure easy access to service the appliance itself, the smoke channels and the ue.
Always maintain adequate distance and protection in order to prevent the product from coming into contact with water.
It is forbidden to install the stove in rooms with a re hazard.
With the exception of sealed installations, it is also forbidden for liquid fuel appliances with continuous or intermittent
operation that draw the combustion air from the room they are installed in or B-type gas heating appliances, with or
without the production of domestic hot water, to coexist in the same room or in interconnecting rooms.
Sealed installation means that the product is certied as sealed and its installation (ducting of the combustion air
and connection to the chimney) is airtight with respect to the installation environment.
A sealed installation does not consume the room’s oxygen but draws all the air from the outer environment (if suitably ducted) and makes
it possible to install the product, therefore, it can be installed in all houses that require a high degree of insulation such as “passive” or
“high energy eciency” houses. Thanks to this technology there is no risk of smoke emissions in the room, hence no air inlets and relevant
ventilation grilles are required in the installation premises.
Consequently, there will be no more draughts of cold air in the room, which would otherwise make it less comfortable and reduce the
overall eciency of the system. The sealed stove may even be installed in a sealed installation that is compatible with the presence of
forced ventilation or in premises that might have negative pressure with respect to the outside.
v
z
BB
x
BB
53
7-CLUB ABSOLUTE STOVE ASSEMBLY
Technical Dept. - All rights reserved - Reproduction prohibited
FITTING THE SIDE PANELS
Take the side panel “B” from the packaging. Insert the holes “z” on the panel “B” into the hooks “v” in the structure.
Use the two screws at the top “x” (see “frame removal”) to fasten the panel “B” to the structure
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for MCZ SUITE AIRMATIC 10 M3 CORE at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of MCZ SUITE AIRMATIC 10 M3 CORE in the language / languages: English as an attachment in your email.
The manual is 8.05 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.