TIMER
6:30
8:00
MO
TU
WE
TH
FR
SA
SU
ON
OFF
20
P1
°C
TIMER
ECO
OFF ON
10
11-REMOTE CONTROL MAX
TIMER settings
TIMER time slot display
In TIMER mode, to display the time slots simply press key D for 2”. With key C one can scroll the 6 time slots freely, quickly checking the
saved settings (gure 8). By pressing key D or A one goes back to the basic display.
Modifying the TIMER time slots
To modify a time slot, display it as described in the previous paragraph and then press key E. The rst parameter to be set will start to ash,
i.e. room temperature. Press key C to modify the value and key E to conrm and set the next parameter. The parameters of a time slot can
be set in the following sequence:
Room temperature. Can be set between 5° and 35°C. 2 dashes “--” appear if set below 5°C or above 35°C, and if this is conrmed, the
programme is disabled(therefore, the product will not be switched on).
Switch-on time. The value is adjusted in 10 minute intervals (from 00:00 to 23:50)
Switch-o time. The value is adjusted in 10 minute intervals (from 00:10:00 to 24:00).
Days of the week in which the programme is active. Monday (MO) will start to ash, followed by the other days of the week. Use key
C to activate/disable the day. The activated days will be displayed on a dark background. When the Sunday (SU) setting is complete,
press key E to exit the editing page and return to the time slots display.
By pressing key D at any time one exits the time slot editing mode, saving all variations conrmed with key E up to that time, and one
goes back to the time slot display condition.
While by pressing key A (or leaving the keypad idle for 30”) one goes directly to the basic display, saving all variations conrmed with key
E up to that time.
Activating the TIMER-ECO time slots
In ECO mode one can activate up to 6 time slots, customising switch-on and switch-o (E1 – E6): by pressing key D for 2” the TIMER
activation/disabling function will appear (gura 9). If the ON option is conrmed one can display/modify the 6 time slots of the TIMER-
ECO with the same procedure described previously for the TIMER. By conrming the OFF option, the TIMER is disabled and the product goes
back to operate in ECO mode without active time slots.
REMOTE CONTROL SYNCHRONIZATION
When the product is started up for the rst time, it may be necessary to synchronize the new remote control with the stove. To do this,
follow these simple instructions:
connect the socket to the stove and turn on the power switch
make sure the selector D on the emergency panel is in the REMOTE position
when the rst message appears on the emergency panel’s display, use a pointed object to press the chased G button (toothpick, etc.)
the panel’s display will show 3 ashing lines “---“. Press the remote control’s on/o button to launch the learning process.
The three ashing lines will disappear from the display and the stove will learn the remote control’s new communication address.
The learning process is also conrmed by an audio signal.
FIG.9
FIG.8
Downloaded from www.Manualslib.com manuals search engine
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Suite 2.0 Comfort Air - 2015 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Suite 2.0 Comfort Air - 2015 in the language / languages: English as an attachment in your email.

The manual is 2,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info