17-CLEANING
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE HEAT EXCHANGER AND THE LOWER COMPARTMENT
Half-way through the winter season, but especially at the end, the compartment through which the exhaust smoke passes will need
to be cleaned. This cleaning process is mandatory in order to facilitate the general removal of all combustion residue, before it becomes
very dicult to remove it due to the humidity compacting it over time.
CAUTION:
cleaning is mandatory to be performed at the end of the season by an authorised and skilled technician so that even
the seals can be replaced.
CLEANING THE EXCHANGER
Open the stove door, remove the brazier and the ash pan. Then remove the inside of the rebox starting from the two side pieces “M”
and “N”. Extract these parts by lifting them slightly upward and pulling them towards you. Then remove the back “L” following the same
procedure. Attention! Once the back “L” is removed, part P which is at the top and rests on part L tends to drop. Also remove this part and
clean any accumulated dirt. Remove the plate “O” by making it come out of the couplings and clean the walls of the rebox with a rigid rod
or a bottle brush so that the dirt falls into the lower compartment.
Reassemble all parts upon completing the cleaning operation.