812472
61
Zoom out
Zoom in
Previous page
1/72
Next page
MP
M
y
nyo
61
38-CLEANING
Technical Dept. - All rights reserved - Reproduction prohibited
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE HEAT EXCHANGER AND THE LOWER COMPARTMENT
Half-way through the winter season, but especially at the end, the compartment through which the exhaust smoke passes will need
to be cleaned.
This cleaning process is mandatory in order to facilitate the general removal of all combustion residue, before it becomes very dicult to
remove it due to moisture compacting it over time.
ATTENTION:
Cleaning is mandatory to be performed at the end of the season by an authorised and skilled technician so that even
the seals can be replaced.
CLEANING THE LOWER COMPARTMENT
To remove ash from the lower compartment open the stove lower door “S” as explained previously. Lower door “M” by turning the handle
and pulling downwards.
Now loosen the four screws y, remove the plate n and the gasket o. Use the nozzle of a vacuum cleaner to remove any ash and soot
that may have built up in the lower exchanger (smoke extractor) indicated by the arrow.
Before putting the cap n back, it is recommended
to change the gasket o”.
After removing and emptying the ash pan P also
clean the lower part of the compartment.
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ STREAM COMFORT AIR 12 M2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ STREAM COMFORT AIR 12 M2 in the language / languages: English as an attachment in your email.

The manual is 12.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ STREAM COMFORT AIR 12 M2

MCZ STREAM COMFORT AIR 12 M2 Installation Guide - English - 76 pages

MCZ STREAM COMFORT AIR 12 M2 User Manual - German - 72 pages

MCZ STREAM COMFORT AIR 12 M2 Installation Guide - German - 76 pages

MCZ STREAM COMFORT AIR 12 M2 User Manual - Dutch - 72 pages

MCZ STREAM COMFORT AIR 12 M2 Installation Guide - Dutch - 76 pages

MCZ STREAM COMFORT AIR 12 M2 User Manual - French - 72 pages

MCZ STREAM COMFORT AIR 12 M2 Installation Guide - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info