694207
74
Zoom out
Zoom in
Previous page
1/76
Next page
PELLET STOVES Chapter 7
INSTALLATION AND USE MANUAL
page 74
Electrical diagrams Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
7.2. VERSION THAT PRODUCES DHW
MOTHERBOARD WIRING KEY
1. Control panel
2. Flow switch (if there is one)
3. Water temperature probe
4. Ambient probe
5. Smoke probe
6. Power supply
7. Spark plug
8. Smoke ejection fan
9. Pump
10. Water temperature overload cut-out
11. Gearmotor
12. Tank temperature overload cut-out
13. Room fan (if there is one)
14. ----------------------------------------
14.1 3-way DHW boiler
14.2 3-way heating
14.3 3-way COM.
15. Anomaly signal (N.O., max 230V 3A)
16. Smoke extractor fan revolutions control
17. External aux signal (N.C., max 230V 3A)
18. Air flow rate sensor
19. Home automation system
20. Room thermostat with potential-free contact
21. Modem
PLEASE NOTE The electrical wiring of individual components is fitted with prewired connectors with different
sizes.
Downloaded from www.Manualslib.com manuals search engine
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Star Hydro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Star Hydro in the language / languages: English as an attachment in your email.

The manual is 5,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ Star Hydro

MCZ Star Hydro Usermanual and installation guide - German - 72 pages

MCZ Star Hydro Usermanual and installation guide - Dutch - 76 pages

MCZ Star Hydro Usermanual and installation guide - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info