812450
15
Zoom out
Zoom in
Previous page
1/62
Next page
dP
dL
dR
dS
6
6
3
5
2
41
6
dR
dP
dC
dF
5
3
dB
4
13
2-INSTALLATION
Bureau d’étude - Tous droits réservés - Reproduction interdite
DISTANCES MINIMALES
Respecter les distances des objets inammables ou sensibles à la chaleur (divans, meubles, revêtements en bois, etc.) comme spécié
dans le schéma ci-dessous.
S’il y a des objets jugés particulièrement sensibles à la chaleur tels que meubles, rideaux, canapés, par précaution, augmenter la distance
du poêle pour éviter toute détérioration due à l’eet de la chaleur.
Distance de sécurité par rapport au matériau combustible (mm)
dR (distance postérieure) 40 AIR/120 COMFORT AIR
dS (distance latérale) 100 AIR/200 COMFORT AIR
dB (distance inférieure) 0
dC (distance supérieure) 800
dP (irradiation frontale) 1000
dF (irradiation au sol) 1000
dL (irradiation latérale) 1000
LÉGENDE
1 SOL 4 SURFACE DE PROTECTION DU SOL
2 MATÉRIAU COMBUSTIBLE FRONTAL 5 SURFACE IRRADIÉE À PROTÉGER
3 ZONE SUJETTE À IRRADIATION 6 SURFACE COMBUSTIBLE ARRIÈRE/LATÉRALE/SUPÉRIEURE
Si le sol est constitué d’un matériau combustible, utiliser une protection en matériau incombustible (acier, verre...) qui protège également
la partie frontale de la chute éventuelle des produits brûlés au cours des opérations de nettoyage.
En présence d’un sol en matériau combustible, il faut toujours monter une surface de protection du sol.
Installer le poêle également détaché de tout mur/surface incombustible, en respectant une circulation d’air minimum 40/120 mm
(arrière) et 100/200 mm (latérale) pour permettre une ventilation ecace de l’appareil et une bonne répartition de la chaleur dans
l’environnement.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ STAR AIR 8 UP M3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ STAR AIR 8 UP M3 in the language / languages: French as an attachment in your email.

The manual is 7.38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ STAR AIR 8 UP M3

MCZ STAR AIR 8 UP M3 User Manual - English - 72 pages

MCZ STAR AIR 8 UP M3 Installation Guide - English - 60 pages

MCZ STAR AIR 8 UP M3 User Manual - German - 72 pages

MCZ STAR AIR 8 UP M3 Installation Guide - German - 60 pages

MCZ STAR AIR 8 UP M3 Installation Guide - Dutch - 60 pages

MCZ STAR AIR 8 UP M3 User Manual - Dutch - 72 pages

MCZ STAR AIR 8 UP M3 User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info