PELLET STOVES Chapter 6
INSTALLATION AND USE MANUAL
page 48
Maintenance and cleaning Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
PROBLEM POSSIBLE CAUSES REMEDY
The smoke extraction
motor does not work.
• No electrical supply to the stove.
• The motor is broken.
• Defective electronic board.
• Control panel broken.
• Check the supply voltage and the
protection fuse.
• Check the motor and capacitor and
replace if necessary.
•
• Replace electronic board.
• Replace the control panel.
The convection air fan
runs continuously.
• Temperature sensor defective or broken.
• Fan broken.
• Check the operation of the sensor
and replace if necessary.
• Check the operation of the motor
and replace if necessary.
Remote control does
not work
• Remote control batteries flat.
• Remote control broken.
• Replace batteries.
• Replace remote control.
In the automatic
position the stove
always runs at full
power.
• Room thermostat set to maximum.
• Temperature sensor defective.
• Control panel defective or broken.
• Reset the thermostat temperature.
• Check the operation of the sensor
and replace if necessary.
• Check the panel and replace if
necessary.
The stove does not run
• Lack of electricity supply.
• Pellet sensor in lockout.
• Fuse blown.
• Pressure switch broken (lockout indicated).
• Smoke outlet or duct blocked.
• Check that the electric socket is plugged
in and that the main switch is in position
“I”.
• Clear lockout by resetting the rear
thermostat, replace the thermostat if
it happens again.
• Replace the fuse.
• Replace the pressure switch.
• Clean the smoke outlet and/or smoke
duct.
ATTENTION
The operations marked in bold type must be carried
out by specialised MCZ personnel.
The manufacturer refuses to accept any responsibility
and the guarantee lapses if this condition is not
respected.