9-CONNECTIONS TO ADDITIONAL DEVICES
Technical Dept. - All rights reserved - Reproduction prohibited
Comfort Air ducting
Comfort Air stoves can channel the air into other rooms through the connection with the accessory pipes to the rear “S” shaped ange
provided as per standard. The recommended maximum duct length is 8 metres per fan. It is advisable to set up ducts of similar length to
distribute the hot air evenly in the various rooms.
The outlet air pipe can reach very high temperatures, even around 150°C: therefore, it must be adequately insulated
with suitable material, especially points that could come in contact with ammable surfaces or parts that are
aected by heat (e.g. change in shades, wiring ducts, plasterboard, etc.). Moreover, persons and animals must be
protected from accidental or intentional contact. In any case, comply with the regulations and laws in force in the
region where the product is installed.
It is recommended to insulate the entire length of the pipe in order to reduce dispersion and increase heat output
in the room.
If you do not wish to channel the air, the hot air may be let out through the rear “V” vent without connecting any pipe.
The “V” vent and the “U” clamp used for fastening are found in a plastic bag inside the hopper of the stove.
1 - ROOM FLOOR
2 - ROOM CEILING
3 - WALL
4 - STOVE
5 - HOT AIR DUCTING
6 - INSULATION
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ MUSA COMFORT AIRMATIC 14 M3 CORE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ MUSA COMFORT AIRMATIC 14 M3 CORE in the language / languages: English as an attachment in your email.

The manual is 10.01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ MUSA COMFORT AIRMATIC 14 M3 CORE

MCZ MUSA COMFORT AIRMATIC 14 M3 CORE User Manual - English - 72 pages

MCZ MUSA COMFORT AIRMATIC 14 M3 CORE User Manual - German - 72 pages

MCZ MUSA COMFORT AIRMATIC 14 M3 CORE Installation Guide - German - 64 pages

MCZ MUSA COMFORT AIRMATIC 14 M3 CORE User Manual - Dutch - 72 pages

MCZ MUSA COMFORT AIRMATIC 14 M3 CORE Installation Guide - Dutch - 64 pages

MCZ MUSA COMFORT AIRMATIC 14 M3 CORE User Manual - French - 72 pages

MCZ MUSA COMFORT AIRMATIC 14 M3 CORE Installation Guide - French - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info