14-SAFETY DEVICES
Technical Dept. - All rights reserved - Reproduction prohibited
SAFETY DEVICES
The product is tted with the following safety devices
PRESSURE SWITCH
Monitors pressure in the smoke duct. It is designed to shut down the pellet feed screw in the event of an obstructed ue or signicant
back-pressure (from wind)
SMOKE TEMPERATURE PROBE
Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset
value.
CONTACT THERMOSTAT IN THE FUEL TANK
If the temperature exceeds the preset safety level, it immediately shuts down the stove.
ELECTRICAL SAFETY
The stove is protected against violent changes in current by a general fuse located in the control panel at the back of the stove. Other fuses
that protect the circuit boards are located on the latter.
SMOKE FAN
If the fan stops, the circuit board immediately shuts o the supply of pellets and an alarm message is displayed.
GEAR MOTOR
If the gear motor stops, the stove will continue to run until the ame goes out due to lack of fuel and until a minimum level of cooling is
reached.
TEMPORARY POWER OUTAGE
When a power outage lasts less than 10’ the stove returns to its previous operating state. If it is longer, it executes a cooling/re-ignition
cycle.
FAILED IGNITION
If during ignition no ame develops, the stove will go into alarm condition.
TAMPERING WITH THE SAFETY DEVICES IS PROHIBITED
If the product is NOT used as described in this instruction manual, the manufacturer declines all liability for any
damage caused to persons and property. The manufacturer furthermore denies any liability for damage to persons
and property arising from failure to observe all the rules contained in the manual and specically:
• All the necessary measures and/or precautions must be adopted when performing maintenance, cleaning and
repairs.
• Do not tamper with the safety devices.
• Do not remove the safety devices.
• Connect the product to an ecient smoke expulsion system.
• First, check that the environment where it is to be installed is properly ventilated.
Only after having removed the cause that triggered the safety system is it possible to start the product again and
therefore restore automatic operation of the probe. This manual will help you understand which anomaly has
occurred, and explain how to operate according to the alarm message displayed on the appliance.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ MIDA AIR 8 S1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ MIDA AIR 8 S1 in the language / languages: English as an attachment in your email.

The manual is 3.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ MIDA AIR 8 S1

MCZ MIDA AIR 8 S1 Installation Guide - English - 52 pages

MCZ MIDA AIR 8 S1 User Manual - German - 32 pages

MCZ MIDA AIR 8 S1 Installation Guide - German - 52 pages

MCZ MIDA AIR 8 S1 User Manual - Dutch - 32 pages

MCZ MIDA AIR 8 S1 Installation Guide - Dutch - 52 pages

MCZ MIDA AIR 8 S1 User Manual - French - 32 pages

MCZ MIDA AIR 8 S1 Installation Guide - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info