PELLET STOVES Chapter 5
INSTALLATION AND USE MANUAL
page 41
Menu structure Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
SONDA
POS.14
CAVO TERMOSTATO
AMBIENTE
5.4.6. Connection to a room thermostat
The room thermostat is not included with the stove
and it must be installed by a specialised technician.
WARNING!
The electrical wires must not be in contact with the
hot parts of the stove.
The stove can also be connected to a room thermostat. The procedure
to follow for the connection of the external thermostat is the following:
Connect the two wires of the cable which come from the room
temperature to the two free terminals of the connector
(position 14 wiring diagram chap.7). To do this it is
necessary to:
o unscrew the protective cap of the probe
o Pass the two wires through the protective cap and
insert them into the hole together with the probe.
o Pull the two wires to carry out connection to the board
corresponding to terminal 14 (see chap.7)
o Close the protective cap again.
PROBE
THERMOSTAT CABLE