812442
11
Zoom out
Zoom in
Previous page
1/32
Next page
11
13-MENU ENTRIES AND OPERATION
Technical Dept. - All rights reserved - Reproduction prohibited
d - Tones
This function is disabled by default. To enable it proceed as follows:
• Press the “menu key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu to conrm.
• Use the arrow keys to scroll through and select ‘’Tones’.
• Press “menu to conrm.
• Using the + - keys, select “On/O.
• Press “menu to conrm and esc to exit.
e - External thermostat (see dedicated chapter)
f - Auto-Eco activation (see dedicated chapter)
To select the Auto-Eco function, proceed as follows:
• Press the “menu key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu to conrm.
• Scroll by using the arrows and select Auto-Eco.
• Press “menu to conrm.
• Use the + - keys to select “On”.
• Press “menu to conrm and esc to exit.
g - Eco stop t (see dedicated chapter)
To select the Eco stop t function, proceed as follows:
• Press the “menu key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu to conrm.
• Scroll with the arrows and select ‘’Eco stop t.
• Press “menu to conrm.
• With the + - keys, insert the minutes (from 1 to 30’).
• Press “menu to conrm and esc to exit.
AUTO ECO MODE (see activation and shutdown paragraph above)
For activation of the Auto Eco mode and time adjustment, see paragraphs 8 f and 8 g respectively.
The option ‘’ECO stop t” can be adjusted to ensure correct operation in the various environments in which the stove can be installed and to
avoid constant shut-downs and start-ups when the room temperature is subject to sudden change (drafts, poorly insulated rooms, etc.).
The ECO shutdown procedure is activated automatically when the power recall device is satised (room probe +1°C or external thermostat
with an open contact), the “ECO stop t starts to decrease the time (factory default 5 minutes, which can be changed from the “Settings”
menu). During this stage, the panel alternates between displaying ON with a small ame and Timer (if active) - Eco active. The minutes
counting down to Eco Stop are shown at the top of the display. The ame moves to P1 and remains there until the set “”ECO stop T time
reaches zero, and if the conditions are still met, goes to the shutdown stage. The ECO stop count is cancelled if one of the devices recalls
power.
When the boiler begins to turn o, the panel displays: O - Eco Active - ashing small ame.
When the stove turns o, OFF-ECO appears on the display with the ame symbol o.
The following conditions have to be met simultaneously for ECO to restart:
• room probe -1°C or external thermostat with a closed contact (for at least 20” in order to prevent false recalls)
• 5 minutes have passed since shutdown.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ GHEA AIR 6 XUP S1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ GHEA AIR 6 XUP S1 in the language / languages: English as an attachment in your email.

The manual is 3.02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ GHEA AIR 6 XUP S1

MCZ GHEA AIR 6 XUP S1 Installation Guide - English - 52 pages

MCZ GHEA AIR 6 XUP S1 User Manual - German - 32 pages

MCZ GHEA AIR 6 XUP S1 Installation Guide - German - 52 pages

MCZ GHEA AIR 6 XUP S1 User Manual - Dutch - 32 pages

MCZ GHEA AIR 6 XUP S1 Installation Guide - Dutch - 52 pages

MCZ GHEA AIR 6 XUP S1 User Manual - French - 32 pages

MCZ GHEA AIR 6 XUP S1 Installation Guide - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info