6.6. CONTROL OF COMBUSTION
PRIMARY AIR
The fireplace stove is equipped with two flanged side holes Ø100 mm
for the inlet of primary air which ensures combustion and helps keep
the glass clean.
. Moving the lever to the left provides the full aperture, and more rapid
combustion, while moving it to the right closes the opening, with slower
burning.
SECONDARY AIR
Adjustment is performed using the same lever as for the primary air.
Secondary air comes out in proportion to the primary air. This balance
is pre-calculated; the user cannot change it, as this may cause incorrect
adjustment. This will prevent excessive combustion.
The use of damp or treated wood emits a higher quantity of
smoke than normal that can dirty glass faster. Also the low
performance of the flue pipe can jeopardise glass cleanliness
since smoke remains in the combustion chamber longer than
normal.
6.7. EMERGENCY SITUATIONS
If for any reason the stove fire needs to be suddenly and quickly put
out or a fire in the flue pipe needs to be put out, proceed as follows:
If time allows, remove the grate and ashes, using a metal
container.
Put the fire out rapidly by means of a dry carbon dioxide (CO
2
)
extinguisher.
Figure 13 Adjustment of
primary/secondary air.
M
A
X
M
I
N
Downloaded from www.Manualslib.com manuals search engine
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Forma Wood at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Forma Wood in the language / languages: English as an attachment in your email.

The manual is 5,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info