PELLET STOVES Chapter 5
INSTALLATION AND USE MANUAL
page 43
Menu structure Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
5.4.6.2. Operating mode with external thermostat
and Eco-Stop
When the external thermostat and Eco Stop are active the stove
actuates the operating conditions described in para. 5.4.6.1, replacing
the command coming from the thermostat at the temperature read by
the probe, so that:
- When the temperature is achieved (thermostat contact open)
the decrease in ECO shutdown T" starts (default 10 minutes,
changeable (*) from inside the TECHNICAL MENU). During this
phase on the small panel display remains ON-ECO ACTIVE, but
the flame drops automatically be one power per minute until it
reaches P1 and stays there until the programmed "ECO
shutdown T" lapses and if the thermostat is still open, it moves
on to the shutdown phase.
Once the stove shutdown conditions are reached,
on the panel the
words "OFF" and “ECO ACTIVE” alternate In this state if the room
temperature drops below that set (thermostat contract closed) the
stove relights without any delay.