PELLET STOVES Chapter 3
INSTALLATION AND USE MANUAL
page 34
Installation and assembly Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
End piece with a
filling tap (D)
and pressure gauge (M)
(accessory)
Grey plug loosened
1 turn
Red plug blocked
3.4.2. System filling
To fill the system, the stove can be equipped with an end piece
(optional)
with a non-return valve (D), for manual filling of the heating
system (if the
optional
is not installed, the filling tap on the main boiler
will be used). During this operation, any air in the system is released
from the automatic vent valve located under the top.
To ensure the valve vents correctly, it is advisable to loosen the grey
cap one turn and to keep the red cap blocked
(see figure)
The filling pressure of the system WHEN COLD must be
1 bar.
During operation, if the system pressure drops (due to evaporation of
dissolved gases in the water) to values lower than the minimum
indicated above, the user must use the filling tap to bring the pressure
back up to its normal pressure.
For proper operation of the stove WHEN HOT, the pressure in the
boiler must be1.5 bar.
To monitor system pressure, the end piece
(optional)
is
equipped with a pressure gauge (M).
Upon completion of this operation, always close the tap.
3.4.3. Water characteristics
The characteristics of the water used to fill the system are very
important to prevent the build-up of mineral salts and the formation of
incrustations along the pipes, in the boiler and in the heat exchangers.
Therefore, please GET YOUR PLUMBER'S ADVICE
CONCERNING:
Hardness of water circulating in the system, to prevent
problems of incrustation and limescale, especially in the
domestic water heat exchanger. (> 25° French)
Installation of a water softener (if water hardness
exceeds 25° French)
Filling the system with treated water (demineralised).
Possibly providing an anti-condensation circuit.
Installation of plumbing bumpers to prevent banging
along the fittings and pipes.
If you have very extensive systems, with a large amount of water, or
which require frequent refilling, the installation of water softening
systems.
It should be remembered that incrustations
drastically reduce performance due to low thermal
conductivity.
Filling tap (D)
Pressure gauge (M)
Vent valve under the top
Downloaded from www.Manualslib.com manuals search engine
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Ego Hydro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Ego Hydro in the language / languages: English as an attachment in your email.

The manual is 5,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ Ego Hydro

MCZ Ego Hydro User Manual - German - 72 pages

MCZ Ego Hydro Usermanual and installation guide - Dutch - 76 pages

MCZ Ego Hydro Usermanual and installation guide - French - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info