3-INSTALLATION
KEY:
(1) CHIMNEY CAP
(2) REFLUX CHANNEL
(3) SMOKE DUCT
(4) THERMAL INSULATION
(5) OUTSIDE WALL
(6) CHIMNEY CONNECTION
(7) SMOKE CHANNEL
(8) HEAT GENERATOR
(9) INSPECTION ACCESS PANEL
MAINTENANCE
The ue must be kept clean, since the deposit of soot or unburned oils reduces the cross-section reducing the draft and thus compromising
the ecient operation of the stove and, if large build-ups accumulate, can catch re. The ue and chimney must be cleaned and checked
by a qualied chimney sweep at least once a year. Once maintenance has been performed, request a written declaration that the system
is safe.
Failure to clean the system jeopardises safety.
CHIMNEY CAP
The chimney cap is a crucial element for the heating appliance to work properly: we recommend a wind proof chimney cap (A), see Figure
7.
The area of the openings for smoke
extraction must be at least double the
cross-section of the smoke duct/ue
system, and arranged so that smoke
extraction is ensured even in strong wind.
The chimney must prevent rain, snow or
animals from entering the chimney. The
height of outow into the atmosphere
must be beyond the reux area due to the
shape of the roof or any obstacles near the
outlet (see Figures 2-3-4-5-6).
CHIMNEY COMPONENTS
FIGURE 7
FIGURE 8