15-ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
A13
Electronic control unit overheating The structure is too hot because the product has been
used for too long at the maximum power or there is
poor ventilation. When the stove is suciently cold,
press button B on the control panel or OFF on the remote
control to cancel alarm A13. Once the alarm is cancelled,
the product can be switched on normally.
A14
Faulty air ow rate sensor This alarm does not block the stove, just a warning is
displayed. Contact an authorised service centre to have
the component replaced.
A18
TRIPPED SAFETY
DEVICES
Open stove door Close the door
Open fuel loading hatch Close the hatch. Lower the fuel level in the tank.
Air pressure switch Draught diculties or brazier clogged.
Check whether the brazier is clogged by scaling and clean
it, if necessary.
Check and if necessary clean the smoke duct and air inlet.
SER
Routine maintenance alert When this ashing message appears upon start-up
it indicates that the preset operating hours before
maintenance is due have elapsed and that an MCZ
qualied technician must be contacted for maintenance.
Exiting the alarm conditions
Follow the procedure described below to restore normal stove operation after an alarm has been triggered:
Put selector D on the rear emergency panel on OFF for a few seconds (about 20 seconds), until the 3 digit alarm identity code
disappears. The red LED stops ashing and the sound signal is silenced by performing the steps below.
Put selector D back in the REMOTE position, to control the operation of the stove via the remote control.
Switch o the remote control and switch it on again if one wants to restart the stove.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ Curve COMFORT AIR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ Curve COMFORT AIR in the language / languages: English as an attachment in your email.

The manual is 3,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ Curve COMFORT AIR

MCZ Curve COMFORT AIR Usermanual and installation guide - English - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info