33-ALARMS
Technical Dept. - All rights reserved - Reproduction prohibited
NEGATIVE PRESSURE INSIDE THE HOPPER WITH FACTORY-SET PARAMETERS AND A DRAUGHT OF 5 Pa (MINIMUM
RECOMMENDED)
POWER P1 P2 P3 P4 P5 VALUES
6 kW 13.7/14.2 Pa 15.1/15.6 Pa 17.1/17.5 Pa 19.1/19.5 Pa 22.0/22.2 Pa Draught
95°C 110°C 125°C 141°C 165°C Smoke temperature
8 kW 13.8/14.3 Pa 15.6/16.1 Pa 17.8/18.0 Pa 21.7/22.2 Pa 26.1/26.6 Pa Draught
104°C 119°C 145°C 148°C 184°C Smoke temperature
10 kW 15.9/16.3 Pa 20.4/20.9 Pa 25.8/26.3 Pa 31.8/32.3 Pa 36.5/37.0 Pa Draught
108°C °C 150°C °C 230°C Smoke temperature
12 kW 16.5/17.3 Pa 20.4/20.9 Pa 25.8/26.3 Pa 31.8/32.3 Pa 36.5/37.1 Pa Draught
118°C 127°C 155°C 172°C 195°C Smoke temperature
14 kW 17.6/18.0 Pa 19.8/20.4 Pa 23.1/23.7 Pa 28.9/29.6 Pa 37.8/38.2 Pa Draught
118°C 131°C 161°C 187°C 210°C Smoke temperature
PLEASE NOTE The indicated negative pressure readings may dier by ±1Pa based on smoke temperature. Likewise, smoke temperature
may dier by ±10°C based on fuel quality or appliance cleanliness.
Changing the smoke fan speed
In order to further improve combustion in critical conditions, you can change the percentage of the parameters for the minimum amount
of incoming combustion air. These changes can be performed upwards in the event of serious diculties in evacuating smoke and/or air
extraction or downwards in the event of excessive draught of the ue.
Refer to AIR RECIPE modication instructions.
AVAILABLE VALUES
-2 -10%
-1 -5%
0 0% (default value)
+1 + 5%
+2 +10%
55


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ CLUB COMFORT AIRMATIC 14 M3 CORE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ CLUB COMFORT AIRMATIC 14 M3 CORE in the language / languages: English as an attachment in your email.

The manual is 10.84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ CLUB COMFORT AIRMATIC 14 M3 CORE

MCZ CLUB COMFORT AIRMATIC 14 M3 CORE Installation Guide - English - 64 pages

MCZ CLUB COMFORT AIRMATIC 14 M3 CORE User Manual - German - 72 pages

MCZ CLUB COMFORT AIRMATIC 14 M3 CORE Installation Guide - German - 64 pages

MCZ CLUB COMFORT AIRMATIC 14 M3 CORE User Manual - Dutch - 72 pages

MCZ CLUB COMFORT AIRMATIC 14 M3 CORE Installation Guide - Dutch - 64 pages

MCZ CLUB COMFORT AIRMATIC 14 M3 CORE User Manual - French - 72 pages

MCZ CLUB COMFORT AIRMATIC 14 M3 CORE Installation Guide - French - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info