14-MENU ITEMS AND OPERATION
Technical Dept. - All rights reserved - Reproduction prohibited
g - Eco Stop T
To select the Eco Stop T function, proceed as follows:
• Press the “menu key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu to conrm.
• Scroll with the arrows and select ‘’T Eco o.
• Press “menu to conrm.
• Enter the minutes with the + - keys.
• Press “menu to conrm and esc to exit.
AUTO ECO MODE
For activation of the Auto Eco mode and time settings, see paragraphs 8 f and 8 g respectively.
The ‘’ECO stop T’ can be adjusted to ensure correct operation in the various environments in which the boiler can be installed and to avoid
constant stopping and starting when the room temperature is subject to sudden change (drafts, poorly insulated rooms, etc.).
The ECO stop procedure is activated automatically when all the power recall devices included in the system conguration” are satised:
room temperature probe/external thermostat (congurations 1-2-3), ow switch (conguration 2), thermostat/ntc (10 kΩß3435) puer
(conguration 4-5) or thermostat/ntc (10 kΩ ß3435) boiler (conguration 2-3). If all the devices present are satised, the time begins
to decrease “T ECO stop (10 minutes default, can be changed in the “Settings” menu). During this phase, the panel alternates between
displaying ON with a small ame and Crono (if active) - Eco active. The minutes counting down to the Eco Stop are shown at the top of the
display. The ame moves to P1 and remains there until the set T Eco Stop” time reaches zero, and if the conditions are still satised, turns
o the boiler. The ECO stop count is cancelled if one of the devices recalls power.
When the boiler begins to turn o, the panel shows: O - Eco Active - ashing small ame.
When the boiler turns o, OFF-ECO appears on the display with the ame symbol o.
The following conditions have to be met simultaneously for the ECO to restart:
• Power recall
• 5 minutes have passed since shut-down.
• TH2O < TSetH2O.
• If the power is recalled by the domestic hot water (DHW), the 5’ are ignored and the boiler starts up as required.
NOTE: In conguration 4 - 5 the Auto Eco mode is enabled automatically. Also when in conguration 2 - 3, with the ‘summer’ function set,
it is enabled automatically. Where it is prescribed that it should be enabled, the mode cannot be disabled.
h - T Pump On
This option enables adjustment of the pump activation temperature.
Select the Pump On T function as follows:
• Press the “menu key.
• Use the arrow keys to scroll through and select “Settings”
• Press “menu to conrm.
• Scroll with the arrows and select T Pump On”.
• Press “menu to conrm.
• Use the + - keys to change the °C.
• Press ‘’menu’ to conrm and ‘’esc to exit.
i - Auxiliary boiler
An additional module (optional) must be installed to allow the start-up of an auxiliary boiler when the main boiler is o or has been
stopped due to an alarm. The default settings have this function disabled. To enable the function, go to the settings menu.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ CLIO HYDRO 16 S2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ CLIO HYDRO 16 S2 in the language / languages: English as an attachment in your email.

The manual is 2.72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ CLIO HYDRO 16 S2

MCZ CLIO HYDRO 16 S2 Installation Guide - English - 48 pages

MCZ CLIO HYDRO 16 S2 Installation Guide - German - 48 pages

MCZ CLIO HYDRO 16 S2 User Manual - German - 36 pages

MCZ CLIO HYDRO 16 S2 User Manual - Dutch - 36 pages

MCZ CLIO HYDRO 16 S2 Installation Guide - Dutch - 48 pages

MCZ CLIO HYDRO 16 S2 Installation Guide - French - 48 pages

MCZ CLIO HYDRO 16 S2 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info