29
5-EMERGENCY PANEL
EMERGENCY PANEL
There is an emergency panel on the product side, designed for any malfunction to be detected and product control if the remote control
should malfunction.
KEY
A
Three-digit display that indicates a variety of product information besides the identication code of any malfunction.
B
GREEN led that indicates:
• OFF = The product is o.
• FLASHING ON = The product is starting up.
• FIXED ON = The product is on.
C
RED led that indicates:
• OFF = The product is on.
• ON AND FLASHING SLOWLY = The product is shutting down.
• ON AND FLASHING QUICKLY = The product is in alarm status (accompanied by a buzzer for the rst 10 minutes).
• FIXED ON = The product is o.
D
3-position selector for the following functions:
• OFF = The product is switched o manually without the remote control.
• REMOTE = The product can only be controlled via remote control.
• ON = The product is switched on manually without the remote control.
E
3-position selector for the power selection:
• MIN = The product runs at MINIMUM power without the remote control and with selector D set to ON.
• MED = The product runs at MEDIUM power without the remote control and with selector D set to ON.
• MAX = The product runs at MAXIMUM power without the remote control and with selector D set to ON F Button for diagnostic functions
regarding the product operation mode.
F
Button for diagnostic functions regarding the product operation mode.
G
Button to connect the product to a new remote control.
SELECTOR “D” MUST BE SET TO THE “REMOTE” POSITION FOR THE PRODUCT TO BE REMOTE CONTROLLED.
Technical Dept. - All rights reserved - Reproduction is prohibited