26-CLEANING
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualied personnel whose technical expertise
includes combustion and electricity.
We recommend for this yearly maintenance to be carried out (with a scheduled service contract). This operation consists of a visual and
functional inspection of the internal components. A summary of the checks and/or maintenance operations that are essential for the
correct operation of the product is provided below.
PARTS/FREQUENCY 23 DAYS 7 DAYS 1 YEAR
UNDER THE USER’S
RESPONSIBILITY
Brazier area
Ash pan
Glass
Lower compartment
Turbulators
BY THE QUALIFIED TECHNICIAN
Complete heat exchanger
Smoke duct
Door gasket
Internal parts
Flue
Circulation pump
Plate heat exchanger
Hydraulic components
Electro-mechanical components
Overpressure silicon damper for combustion chamber
Door closure operation
CLEANING THE CONTROL PANEL DISPLAY
ATTENTION!!
THE PANEL DISPLAY IS VERY DELICATE, IT IS SUPPLIED WITH A PROTECTIVE FILM.
RECOMMENDATIONS FOR CLEANING:
Clean using a soft cotton cloth, which should be dry or slightly moist.
Do not use aggressive detergents or polyester materials.
Do not use abrasive sponges or powder detergents nor solvents such as alcohol and petrol, since they may damage the surface of the
device.
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ AKI Hydromatic 24 M2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ AKI Hydromatic 24 M2 in the language / languages: English as an attachment in your email.

The manual is 9.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ AKI Hydromatic 24 M2

MCZ AKI Hydromatic 24 M2 User Manual - English - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info