27-SAFETY DEVICES AND ALARMS
WRITTEN ON THE
DISPLAY TYPE OF PROBLEM SOLUTION
A20
AUX PROBE
Auxiliary probe failure
Possible component fault.
Check that the probe inserted in the system respects
the characteristics specied in the instructions (see
external probe).
Contact an authorised service centre to have the
component checked and, if needed, replace the
component.
A21
PRESSURE SWITCH
ES SIC3
Open stove door Close the door
Open fuel loading hatch Close the hatch.
Lower the fuel level in the hopper.
Air pressure switch Draught diculties or clogged brazier.
Check whether the brazier is clogged by deposits and
clean it, if necessary.
Check and if necessary clean the smoke duct and air
inlet.
A22 Room probe failure
Possible fault in the safety component. Contact an
authorised service centre to have the component
checked and, if needed, replace the component.
A23 Brazier not closed Possible obstruction in the brazier. Clean.
If the problem persists, contact a service centre.
Exiting the alarm conditions
NEVER open the stove door whilst it is either in the initial ignition or on its shut down cycle, pellets will still be
smouldering or therefore volatiles may be present.
ATTENTION!
If during operation or initial ignition you encounter combustion smoke leakage into the room from the appliance
or the ue, then please switch o the appliance, ventilate the room and contact the installation / service technician
immediately.
When the stove enters an alarm state, an automatic cooling/shut-o phase begins, at the end of which the cause of the alarm is displayed
on the small panel.
Follow the procedure described below to restore normal stove operation after an alarm has been triggered:
• Cancel alarms A01, A02, A03, A05, A21 only from the panel on the stove.
• Cancel the other alarms from the App.
If the indicated actions do not solve the problem, the alarm condition will occur once again with dierent timing based on the alarm type:
in this case, contact technical assistance.
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for MCZ AKI HYDROMATIC 24 M1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of MCZ AKI HYDROMATIC 24 M1 in the language / languages: English as an attachment in your email.

The manual is 8.23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of MCZ AKI HYDROMATIC 24 M1

MCZ AKI HYDROMATIC 24 M1 Installation Guide - English - 48 pages

MCZ AKI HYDROMATIC 24 M1 User Manual - German - 64 pages

MCZ AKI HYDROMATIC 24 M1 Installation Guide - German - 52 pages

MCZ AKI HYDROMATIC 24 M1 Installation Guide - Dutch - 48 pages

MCZ AKI HYDROMATIC 24 M1 User Manual - Dutch - 64 pages

MCZ AKI HYDROMATIC 24 M1 Installation Guide - French - 48 pages

MCZ AKI HYDROMATIC 24 M1 User Manual - French - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info