6. Timer operation
Timer ON setting:
- When the air-conditioner is OFF, press the “Timer” button and select a desired ON time through the
temperature and time setting buttons.
- “Preset ON Time” is displayed on the operation panel.
- ON time can be regulated at any time in 0-24 hours.
Timer OFF setting
- When the air-conditioner ON, press “Timer” button and select a desired OFF time through the
temperature and time setting buttons.
- “Preset OFF Time” is displayed on the operation panel.
- OFF time can be regulated at any time in 0-24 hours.
7.SLEEP CONTROL FUNCTION
- While in cooling mode, press the SLEEP key to set the temperature. It increases1 ℃ after an hour and at
most increases 2 ℃ after 2 hours.
- While in heating mode, press the SLEEP key to set the temperature. It decreases 1 ℃ after an hour and
at most decreases 2 ℃ after 2 hours.
- Press the SLEEP key again can cancel the setting.
8. Drainage
Internal Tank Water Full Alarm Function
The inner water tank in the air-conditioner has one water level safety switches, it controls
water level. When water level reaches an anticipated height, the water full indicator lamp lights
up. (If water pump is damaged, when the water is full, please remove the rubber blockage at the
bottom of unit, and all water will drain outside.)
CONTINUOUS DRAINGE
- When you plan to leave this unit unused for a long time, please remove the rubber blockage
from the drainage hole at the bottom of unit, and connect a drain hose to the lower fixing clip.
All the water in the water tank will drain outside.
- You can drain the water as the above when the unit working at the HEAT mode.
- If water pump is damaged, continuous drainage can be used, and under this condition, the
water pump is not activated. The unit can also work well.
If water pump is damaged, intermittent drainage can also be used. Under this condition, when the
water full indicator lamp lights up, please connect a drain hose to the lower fixing clip, then all the
water in the water tank will drain outside. The unit can also work well.
7. Installation Explanations
1. Installation Explanations:
- A removal air-conditioner shall be installed in the flat and empty place all around. Don’t block
the air outlet, and the required distance around should be at least 30cm. (See Fig.8)
- Should not be installed in dry cleaner.
- Socket wiring should be in accordance with the local electric safety requirements.
7. Installation Explanations