Installation instructions
Piping Joints Thermal Insulation:
Wrap the piping joints with thermal
insulation materials and then wrap
with a vinyl tape.
Piping Thermal Insulation:
a. Place the drain hose under the piping.
b. Insulation material uses polythene foam over 6mm in thickness.
Note: Drain hose is prepared by user.
Drain pipe should point downward for easy drain flow.
Do not arrange the drain pipe twisted, sticking out or wave
around, do not immerse the end of it in water.
If an extension drain hose is connected to the drain pipe, make
sure to thermal insulated when passing along the indoor unit.
When the piping is directed to the right, piping, power
Cord and drain pipe should be thermal insulated and
fixed onto the back of the unit with a piping fixer.
Thermal insulation
wrapped with vinyl type
Small
pipe
Large pipe
Thermal insulation
tube
Power cord 1
(for heat-pump)
Power cord
Defrost cable(for heat-pump)
Drain hose
(prepared by user)
A. Insert the pipe fixer to the slot.
B. Press to hook the pipe fixer onto the base.
Base
Base
Base
Piping fixer
Piping fixer
Hook here
Insert here
drain
hose
drain
hose
large
pipe
large
pipe
small
pipe
small
pipe
b. Pre-tighten them with fingers at first, then use the wrenches.
For T3 climate kind models, 18K and 24K Liquid Side is ( 6 or 1/4 inch).
a. Connect indoor unit pipes with two wrenches. Pay special attention
to the allowed torque as shown below to prevent the pipes, connectors
and flare nuts from being deformed and damaged.
Piping Connection:
Pipe sizeModel
Liquid Side (1/4 inch)7,9,12,18K
12,18K
7,9K
22,24K
22,24K
1.8kg.m 17mm 0.6mm
0.6mm
0.6mm
0.6mm
0.6mm
22mm
24mm
22mm
27mm
3.5kg.m
3.5kg.m
5.5kg.m
7.5kg.m
Liquid Side (3/8 inch)
Gas Side (1/2 inch)
Gas Side (3/8 inch)
Gas Side (5/8 inch)
Torque Nut width
Min.thickness
18
If refrigerant of the appliance is R407C or R410A, 18K Liquid Side is
( 10 or 3/8 inch),and Gas side is ( 16 or 5/8 inch).
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Maxicool SKL-70HOA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Maxicool SKL-70HOA in the language / languages: English, Dutch as an attachment in your email.

The manual is 1,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info