BEFORE PERFORMING
ELECTRICAL WORK, READ
THESE REGULATIONS
1.
All wiring must comply with local and
national electrical codes, and must be
installed by a licensed electrician.
2.
All electrical connections must be made
according to the Electrical Connection
Diagram located on the panels of the
indoor and outdoor units.
3.
If there is a serious safety issue with
the power supply, stop work immediately.
Explain your reasoning to the client, and
refuse to install the unit until the safety
issue is properly resolved.
4.
Power voltage should be within
90-100% of rated voltage. Insufficient
power supply can cause malfunction,
electrical shock, or fire.
If connecting power to fixed wiring,
install a surge protector and main
power switch with a capacity of 1.5
times the maximum current of the unit.
5.
6.
If connecting power to fixed wiring,
a switch or circuit breaker that
disconnects all poles and has a contact
separation of at least 1/8in (3mm) must
be incorporated in the fixed wiring.
The qualified technician must use an
approved circuit breaker or.
7.
Only connect the unit to an individual
branch circuit outlet. Do not connect
another appliance to that outlet.
8.
Make sure to properly ground the
air conditioner.
9.
Every wire must be firmly connected.
Loose wiring can cause the terminal to
overheat, resulting in product
malfunction and possible fire.
10.
Do not let wires touch or rest against
refrigerant tubing, the compressor, or
any moving parts within the unit.
11.
If the unit has an auxiliary electric
heater, it must be installed at least 1
meter (40in) away from any
combustible materials.
Page 17
Step 6: Connect signal cable
The signal cable enables communication between
the indoor and outdoor units. You must first
choose the right cable size before preparing it for
connection.
Cable Types
Indoor Power Cable (if applicable):
H05VV-F or H05V2V2-F
Outdoor Power Cable: H07RN-F
Signal Cable: H07RN-F
Minimum Cross-Sectional Area of
Power and Signal Cables
Other Regions
Rated Current of
Appliance (A)
Nominal Cross-Sectional
Area (mm²)
> 3 and 6 0.75
> 6 and 10 1
> 10 and 16 1.5
> 16 and 25 2.5
> 25 and 32 4
> 32 and 40 6
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal
cable, fuse, and switch needed is determined
by the maximum current of the unit. The
maximum current is indicated on the nameplate
located on the side panel of the unit. Refer to
this nameplate to choose the right cable, fuse,
or switch.
Indoor Unit
Installation
WARNING
BEFORE PERFORMING AN Y ELECTRICAL
OR WIRING WORK, TURN OFF THE MAIN
POWER TO THE SYSTEM.
North America
Appliance Amps (A)
AWG
10 18
13 16
18 14
25 12
30 10
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Maxicool Luna - LMD-AE-09HDI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Maxicool Luna - LMD-AE-09HDI in the language / languages: English as an attachment in your email.

The manual is 9,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Maxicool Luna - LMD-AE-09HDI

Maxicool Luna - LMD-AE-09HDI Additional guide - English - 62 pages

Maxicool Luna - LMD-AE-09HDI Additional guide - English - 8 pages

Maxicool Luna - LMD-AE-09HDI User Manual - English - 19 pages

Maxicool Luna - LMD-AE-09HDI Additional guide - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info