TROUBLESHOOTING TIPS
Malfunctions
Unit does not
start
Unit not cooling
or heating
(Cooling/ heating
models only)
room very well
while air flowing
out from the air
conditioner
Cause
Power cut
Unit may have become
unplugged.
Fuse may have blown.
Battery in Remote controller may
have been exhausted.
The time you have set with timer
is incorrect.
Wait for power to be restored.
Check that plug is securely in wall
receptacle.
Replace the fuse.
Replace the battery.
Wait or cancel timer setting.
Set temperature correctly. For
detailed method please refer to
" "Using remote control section.
Clean the air filter.
Close the doors or windows.
Clear obstructions away first, then
restart the unit.
Wait.
Inappropriate temperature
setting.
Air filter is blocked.
Doors or Windows are open.
Air inlet or outlet of indoor or
outdoor unit has been blocked.
Compressor 3 minutes
protection has been activated.
If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model.
Notes: Do not attempt to repair the unit yourself.
Always consult an authorised service provider.
What should be done?
10. Auto-restart function
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator
on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the
remote controller. For the unit with Auto-restart feature, when the power restores, the unit
restarts automatically with all the previous settings preserved by the memory function.
For some models, the machine is special designed with Auto-restart function for the open
angle of the horizontal louver.Power failure during operation or pressing the ON/OFF button
on the remote controller will stop the unit completely.When the power restores or pressing
the ON/OFF button on the remote controller again,the unit restarts automatically with all the
previous settings including the open angle of the horizontal louver by the memory function.
So we strongly suggest that the open angle of the horizontal louver should not be set too
small,in case the condensed water forms and drops from the horizontal louver. Press the
AUTO/COOL button under the front panel and the open angle of the horizontal louver will be
restored to the standard angle when the condensed water forms on the horizontal louver.
11. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.
Disconnect the unit with power and then re-connect the unit with power again. Push the
ON/OFF button on the remote controller to restart operation.
12. The protection of outdoor low temperature(on some models)
The protection of outdoor low temperature can be activated only in the HEATING mode.
The unit will stop operating and display "P3" on the LCD window of the indoor unit when the
O O
outdoor temperature is or lower than 5 F(-15 C) for one hour, but the indoor unit in this situation
can still receive the signal from the remote controller.The unit will restart automatically with all the
previous settings preserved by the memory function when the outdoor temperature is or higher
O O
than 11 F(-12 C) for 10 minutes and the compressor stop operating for more than one hour, or
O O
when the outdoor temperature is or higher than 41 F(5 C) for 10 minutes.
14
If one of the following faults occurs, s
and then connect it in again. If the problem still exists, disconnect the power and contact the
nearest customer service center.
top the air conditioner immediately, disconnect the power
Fuse blows frequently or circuit breaker trips frequently.
Other objects or water fall into the air conditioner.
The remote controller won't work or works abnormally.
Trouble
OPERATION/RUN indicator or other indicators continue flashing.
If one of the following code appears on the display area :
E0,E1,E2,E3.....or P0,P1,P2,P3......
TROUBLESHOOTING TIPS
Troubleshooting guide
8. Dripping water may generate on the surface of the indoor unit when cooling in a high
relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed.
9. Heating mode (For cooling and heating models only)
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
during heating operation. When the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly. At the same time, heat loading of the air conditioner
increases due to larger difference between indoor and outdoor temperature. If a
comfortable temperature can't be achieved by the air conditioner, we suggest you use a
supplementary heating device.
7. The air conditioner runs function after turning off the unit.
When turning off the unit under COOL(AUTO COOL, FORCED COOL) and DRY mode, the air
conditioner will run function for 7-10 minutes,
then stop the operation and turn
off the unit automatically.
Anti-mildew
Anti-mildew if turns off on HEAT mode, the unit will
continue operating for about 30 seconds at LOW fan speed,
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Maxicool LMD-12HDI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Maxicool LMD-12HDI in the language / languages: English as an attachment in your email.

The manual is 0,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Maxicool LMD-12HDI

Maxicool LMD-12HDI Installation Guide - English - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info