587374
5
Zoom out
Zoom in
Previous page
1/8
Next page
7
8
OPERATING INSTRUCTIONS
Airflow direction control
Adjust the air flow direction properly, otherwise it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal louver using the remote
controller.
Adjust the vertical louver manually.
To set the vertical air flow(Up--Down) direction
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow
direction. The horizontal louver can be moved at
O
a range of 6 for each press, or swing up and down
automatically. Please refer to the REMOTE
CONTROLLER OPERATION MANUAL for details.
To set the horizontal air flow direction (left - right)
Move the vertical louver manually to adjust the air
flow in the direction you prefer.
IMPORTANT: Before adjusting the vertical louvers,
the supply power must be disconnected.
For some models, the vertical louver can be adjusted
by using the remote controller. Please refer to the
REMOTE CONTROLLER OPERATION MANUAL
for details.
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
Do not move the horizontal louver manually unless it is
necessary. Always use the remote controller.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
Do not operate unit with horizontal louver in closed
position.
When the air conditioner is connected to power (initial
power), the horizontal louver may generate a sound for
10 seconds, this is a normal operation.
CAUTION
,,
,,
,,
,,
OPERATING INSTRUCTIONS
Manual switch
Panel
AUTO/COOL
Range
Range
Vertical
louver
NOTE: This manual does not include Remote Controller Operations, see the
<<Remote Controller Instruction>> packed with the unit for details.
Manual operation
Operating temperature
Mode
Temperature
Room temperature
Outdoor temperature
1. Optimum performance will be achieved within these operating temperatures.If air
conditioner is used outside of the above conditions, certain safety protection features
might come into operation and cause the unit to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over
80%) , condensed water may drip out of the unit. Please sets the vertical air flow louver to
its maximum angle (vertically to the floor), and set HIGH fan mode.
Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature
O O
is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to
guarantee it running smoothly.
NOTE:
Cooling operation
Heating operation Drying operation
-15 50 5 122
For the models with low
temperature cooling system
0 50
32 122
-15 30
5 86
0 50
32 122
Open and lift the front panel up to an angle
until it remains fixed with a clicking sound.
One press of the manual control switch will
lead to the forced AUTO operation. If press
the switch twice within five seconds, the unit
will operate under forced COOL operation.
Close the panel firmly to its original
position.
This switch is used for testing purposes
only. You had better not choose it.
To restore the remote controller operation,
use the remote controller directly.
CAUTION:
1
3
2
NOTE: The unit must be turned off before
operating the manual control button. If the
unit is operational, continue pressing the
manual control button until the unit is off.
O O
17 C~32 C
O O
(62 F~90 F)
O O
0 C~30 C
O O
(32 F~86 F)
O O
10 C~32 C
O O
(50 F~90 F)
Units are equipped with a switch to run emergency operation mode. It can be accessed by
opening the front panel. This switch is used for manual operation in case the remote controller
fails to work or maintenance necessary.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Maxicool LMD-09HDI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Maxicool LMD-09HDI in the language / languages: English as an attachment in your email.

The manual is 0,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Maxicool LMD-09HDI

Maxicool LMD-09HDI Installation Guide - English - 2 pages

Maxicool LMD-09HDI Additional guide - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info