Installation instructions
22
Adjustment of refrigerant:
Max pipe length(m)
20
(L-10) 0.02
Drain pipe connection
Additional refrigerant(Kg)
Epoxy glue
1~1.5m
Over 1/100
After air exhaust, check all the joints of indoor and outdoor units with a halogen
detector or suds before wrapping to ensure there is no leakage.
The refrigerant volume of the models in this manual are based on
using 10m connecting pipes. If your connecting pipes are longer than10m,
additional refrigerant should be charged according to pipe length(L).
The additional refrigerant must be charged in the condition that it is running in the system.
The refrigerant should be charged to the system from the service port of the low pressure valve.
Be careful not to allow air enter the system while adding refrigerant.
Connect the large end (inner dia 25mm, outer dia 32mm) of the drain hose to the drain port
of the main unit, then clamp it well.
Measure the distance from the drain pipe to the outside of wall, then cut a PVC tube of
according to this length.
Apply epoxy glue onto the small end (outer dia 21mm) of the drain hose, then connect it to
the PVC tube.
(inner dia 22mm)
Direct the other end of the PVC tube to the outside of the wall, connect to a downward
pipe with a elbow.(make sure to stick the joints well with epoxy glue)
If the suspending section of the indoor drain pipe exceeds 2m, a supporting bracket should be made
to fix it every 1-1.5m; The drain pipe must tilt downward with a gradient over 1/100 to ensure easy
drainage. Do not allow too many bends on the drain pipe that may block water from draining.
25
25
NOTE:When adjusting R407Crefrigerant into the system, make sure to charge in liquid state.
Otherwise, chemicalcomposition of refrigerant (R407C) inside the system may change and thus
affect performance of the air conditioner.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Maxicool CLK120H4C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Maxicool CLK120H4C in the language / languages: English as an attachment in your email.

The manual is 1,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info