SFX SERIES USER’S GUIDE
Rev 2.2 19
Carrier Type
S S
Auto
Viterbi
S2 S2
Auto
RF Metric Description
marginally too high (80% to 89%).
Green – signal level is in the acceptable AGC operating range
(30% to 80%).
Eb/No This value represents the calculated Eb/No (in dB) at the input to
the tuner. This value is derived from the C/N value, with
compensation for modulation scheme, Reed-Solomon FEC, Viterbi
FEC rate, and symbol rate of the carrier.
C/N This value represents the estimated carrier to noise ratio (in dB) at
the L-Band input to the tuner. The format of this value is x.y dB.
Mod Standard Selects the modulation standard as either DVB-S or DVB-S2
Viterbi Rate This is the factor used in the FEC of the satellite data for recovery
of data.
Code Rate
Alpha Factor
Viterbi BER This is the number of bit errors encountered during a fixed frame
length of incoming data. This data is obtained from the tuner
demodulator chip and is converted to a BER value in the form x.y
E -z.
LNB Offset This indicates what the current LNB offset is, based on the
automatic LNB drift tracking mechanism of the tuner. This value is
added or subtracted from the set frequency in the DVB Carrier
definition to tune to the carrier.
Refresh Shows the period of the refresh of the RF metrics on this page.
NOTE: The accuracy of the values reported for C/N and Eb/No are typically ±1 dB up to a C/N of 15 dB (BER of 1 x
10
-12
). With C/No values higher than 15 dB, the accuracy degrades. (For example, a DVB-S signal can be considered
error free at greater than 7 dB Eb/No at 7/8 Viterbi, 4 dB Eb/No at 1/2 Viterbi).
Controlling the Receiver with SNMP
The Simple Network Management Protocol (SNMP) is a set of protocols for managing complex networks. SNMP
works by sending messages, called Protocol Data Units (PDU’s), to different parts of a network, providing a standard
mechanism for network control and monitoring. SNMP-compliant devices, called agents, store data about themselves
in Management Information Bases (MIB’s) and return this data to the SNMP requestor.
The advantage of using SNMP is that its design is simple, hence it is easy to implement on a large network. It does not
take a long time to set up, puts very little stress on a network and is easy for users to program. Its simple design also
allows it to be easily updated so that it can expand for future network requirements.
SNMP has been implemented in the SFX Series satellite receivers to provide users with flexibility in network
management.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Max SFX Series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Max SFX Series in the language / languages: English as an attachment in your email.

The manual is 4,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info