Ventilation
The main consideration when installing any refrigeration unit into
a fitted kitchen is ventilation. The heat removed from the cooling
compartment needs to be dissipated into the atmosphere. Incorrect
ventilation can lead to premature compressor failure, excessive
power consumption and total system failure. For products intended
to be installed into a tall housing unit, the following requirements need
to be met:-
Important
Please follow the instructions to install this unit.
300
300
plan view of cut out and ventilation
gaps
The top of the cabinet needs to be
vented into the room
Recommended size of vent opening:
500 x 35mm
If the furniture does not allow free air
into the room then a plinth vent, or
other means of ventilation needs to be
provided to ensure a natural flow of air
There should be space at the rear
of the cabinet to allow cool air to be
drawn over the condenser.
Recommended:
500 x 35mm
An air intake
should be
provided
somewhere in
the cabinet run
to allow free
air in. In this
example, a plinth
vent is shown
underneath the
refrigerator .
A thin section of
the plinth can be
removed to allow
air into the unit
(recommended
600mm x 10mm)
Refrigerator
outline
Min 30mm
A hole should be cut in the support-
ing shelf, as shown below
fig. 6
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Matrix MFC701 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Matrix MFC701 in the language / languages: English as an attachment in your email.

The manual is 0,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info