785626
21
Zoom out
Zoom in
Previous page
1/24
Next page
TECHNISCHE GEGEVENS
NL / Solar ChargeMaster 60 MPPT-MB 21
6 TECHNISCHE GEGEVENS
6.1 SPECIFICATIES
Model Solar ChargeMaster 60 MPPT-MB
Artikelnummer. 131906000
Nominale accuspanning (UNOM) 12V, 24V en 48V (Automatische detectie)
SOLAR-INGANG @ UNOM = 12V @ UNOM = 24V @ UNOM = 48V
Maximaal aangesloten Solar vermogen 900Wp 1800Wp 3600Wp
Maximaal Solar-ingangsvermogen* 800W 1600W 3200W
MPPT spanning bij vol vermogen 15 V ~ 115 V 30 V ~ 115 V 60 V ~ 115 V
Absolute maximale PV spanning 145VDC 145VDC 145VDC
MPP tracker Ja, geïntegreerde MPP tracker
Opstartspanning: Accuspanning + 3VDC
Maximale stroom Solar ingang 50ADC
EU rendement >97%
Maximaal statisch omvormer rendement >98%
Statisch MPPT rendement >99%
ACCU-UITGANG @ UNOM = 12V @ UNOM = 24V @ UNOM = 48V
Maximale laadstroom (IMAX) 60 A 60 A 60 A
Laadspanning, Absorption: 14.25V
(Tractie: 14.45V)
28.5V
(Tractie: 28.9V)
57.0V
(Tractie: 57.8V)
Laadspanning, Float; 13.25V
(AGM, gel: 13.8V, MLi:
13.5V)
26.5V
(AGM, gel: 27.6V,
MLi: 27.0V)
53.0V
(AGM, gel: 55.2V,
MLi: 54.0V)
Uitschakelen / inschakelen bij onderspanning 8.5V / 9.0V 17.0V / 18.0V 34.0V / 36.0V
Uitschakelen / inschakelen bij overspanning 15.0V / 14.5V 30.0V / 29.0V 60.0V / 58.0V
Accutemperatuurcompensatie –30 mV/°C –60 mV/°C –120 mV/°C
DC stroomverbruik (‘s nachts): <1mA <1mA <1mA
DC stroomverbruik (aan, niet-ladend): <130mA <130mA <130mA
Laadkarakteristiek: Drietraps (Bulk, Absorption, Float)
Accutypes**: Open loodzuur, AGM, Gel, Tractie, Mastervolt MLi
ALGEMEEN
Galvanische scheiding tussen PV en accu Nee, gemeenschappelijke negatieve geleider
Afmetingen in mm (h x w x d): 168 x 398 x 107 mm; zie ook paragraaf 6.2
Gewicht: 5.5 kg
Temperatuurbereik, normaal bedrijf –20°C TAMB +55°C
Temperatuurbereik, vol vermogen –20°C TAMB +40°C (geen vermogensafname)
Temperatuurbereik, niet werkend –40°C TAMB +75°C (opslagtemperatuur)
Relatieve luchtvochtigheid 5% tot 95% niet-condenserend
Beschermingsklasse IP23
Geschikt voor aansluiten op MasterBus Ja
Aansluitingen Schroefklemmen, max. draaddiameter 35mm2
* Automatische beperking van het ingangsvermogen. Overtollig vermogen wordt niet geconverteerd
** Raadpleeg paragraaf 4.1.2 of 4.2.4 voor instellingen accutype.
Specificaties kunnen worden gewijzigd zonder voorafgaande kennisgeving.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Solar ChargeMaster SCM60 MPPT-MB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Solar ChargeMaster SCM60 MPPT-MB in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info