8 EN / SCM20 & SCM40 PWM User’s Manual
2.6.1 Low voltage disconnect function
There are two ways to protect the battery from too deep
discharges:
Static: the Load output switches off if the battery
voltage drops below the Disconnect threshold voltage.
Dynamic: the Load output switches off depending on
both battery voltage and load current.
The Load output switches on again if the battery voltage
rises above the Reconnect threshold value.
The Low voltage disconnect function can only be used if
the load is connected to the Load output (see section 3.5)
Static Low voltage disconnect function:
Indication Disconnect
threshold Reconnect
threshold
10.8 / 21.6 10.8V / 21.6V 11.6 V / 23.2V
10.9 / 21.8 10.9V / 21.8V 11.7 V / 23.4V
11.0 / 22.0 11.0V / 22.0V 11.8 V / 23.6V
11.1 / 22.2 11.1V / 22.2V 11.9 V / 23.8V
11.2 / 22.4 11.2V / 22.4V 12.0 V / 24.0V
11.3 / 22.6 11.3V / 22.6V 12.1 V / 24.2V
11.4 / 22.8 11.4V / 22.8V 12.2 V / 24.4V
11.5 / 23.0 11.5V / 23.0V 12.3 V / 24.6V
11.6 / 23.2 11.6V / 23.2V 12.4 V / 24.8V
11.7 / 23.4 11.7V / 23.4V 12.5 V / 25.0V
11.8 / 23.6 11.8V / 23.6V 12.6 V / 25.2V
Dynamic Low voltage disconnect function:
Indication Disconnect threshold Reconnect
threshold
at full load at no load
11.0V
22.0V
11.6V
23.2V
12.4 V
24.8V
11.1V
22.2V
11.6V
23.2V
12.5 V
25.0V
11.2V
22.4V
11.6V
23.2V
12.6 V
25.2V
11.4V
22.8V
11.6V
23.2V
12.7 V
25.4V
11.6V
23.2V
11.6V
23.2V
12.8 V
25.6V
2.6.2 Battery type
Indication Battery type
Gel
Flooded (liquid)
AGM
2.6.3 Load mode
Indication Load mode
Always on Mode: the load output
is always switched on
Dusk to Dawn Mode: the load
output is switched on between
sunset and sunrise.
PV input threshold voltage:
5.0/10.0V
Evening Mode: The load output
will be switched on for 2~9 hours
after sunset.
Manual Mode. The load output
can be switched on and off
manually by pressing MENU
shortly.
NOTES:
You can test the operation of the Load output manually
by holding MENU pressed for 3 seconds. Press MENU
again to switch off the load again or the load will switch
off automatically after 1 minute.
If the Manual Load Mode is selected (“USE”), you can
switch on and off the Load output manually by pressing
MENU shortly. In this case the protections against fault
conditions for overload, short circuit, overheating or
under and over voltage will be ignored!
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Solar ChargeMaster SCM20 PWM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Solar ChargeMaster SCM20 PWM in the language / languages: English as an attachment in your email.

The manual is 0.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info