785651
3
Zoom out
Zoom in
Previous page
1/4
Next page
AC Master Interface – User and Installation Manual
3
3 INSTALLATION
Steps:
The step numbers correspond to the numbers in the drawing.
Mount the AC Master Interface to any flat surface. The AC Master Interface
comes with a DIN rail mount option. Alternatively, use the two mounting
holes.
Insert the RJ11 cable (included, 1m) and connect to the remote input of the
AC Master inverter.
Insert the MasterBus cable (included, 1m) and make sure that the MasterBus
network is properly terminated at the two ends with a terminating device (one
included).
A flashing LED indicates that the MasterBus communication is working.
4 OPERATION
The following table shows the AC Master Interface MasterBus functions.
MONITORING DESCRIPTION ADJUSTABLE RANGE
General
Device state Shows the current operation mode:
Not connected, On, Bypass, Alarm
(read only)
On/Off Button to switch the device on or off [default: On] On, Off
Battery
Voltage Battery voltage (read only)
AC input
Voltage Input voltage (read only)
Power Input power (read only)
AC output
Voltage Output voltage (read only)
Power Output power (read only)
Frequency Output frequency (read only)
ALARM
High battery High battery voltage alarm (read only)
Low battery Low battery voltage alarm (read only)
Temperature AC Master temperature is too high (read only)
Overload Output overload (read only)
System error AC Master error (read only)
CONFIGURATION
Device
Language Interface menu language on a monitoring device connected
to the MasterBus network [default: English]
EN, NL
Name User defined device name, visible throughout the MasterBus
network [default: AC Master]
Up to 12 Characters
Type AC master model (read only)
EVENTS
Event target Select a target device in your system System dependent
Event command Select a command Target dependent
Event data Select the way the command should act on the source See relevant product manual
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt MasterBus AC Master Interface at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt MasterBus AC Master Interface in the language / languages: English as an attachment in your email.

The manual is 0.88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info