786811
9
Zoom out
Zoom in
Previous page
1/20
Next page
9
4 INSTALLATION
WARNING
Be sure that all AC power sources are
switched off or disconnected during
installation.
WARNING
External fuses and earth leakage switches
must be integrated in the wiring of all inputs
and outputs of the Mass Systemswitch.
4.1 GENERAL
During installation and commissioning of the Mass
Systemswitch the Safety Guidelines and Measurements
are applicable at all times. See section 2 of this manual.
After unpacking, check the Mass Systemswitch for
possible damage. Do not use the Mass Systemswitch if
the cabinet is damaged.
4.2 ENVIRONMENT
Obey the following stipulations during installation:
The Mass Systemswitch is designed for indoor use
only.
Humidity: 0-95% non-condensing.
Mount the Mass Systemswitch on a solid surface, with
the connecting cables downwards.
4.3 TOOLS REQUIRED FOR INSTALLATION
We recommend as a minimum tool kit:
Flat blade screw driver 1.0 x 4.0 mm to fix the screw
terminals of the AC wiring.
Flat blade screw driver 0.6 x 3.5 mm for connection of
the remote panel.
Tools to fix the screws / bolts 6mm) with plugs to
mount the cabinets to a surface.
Phillips screw driver number 2 to open the connection
area of the Mass Systemswitch.
4.4 MOUNTING OF THE CABINET
Take the following steps to mount the cabinet:
1. Determine for the four mounting spots on the basis of
the outline drawings (section 6.2 Dimensions).
2. Fix the screws 6mm) into the surface but do not
tighten them entirely.
3. Place the housing over the screws.
4. Fix the housing by fastening the screws securely.
Figure 6: mounting of the cabinet
4.5 OPENING THE CONNECTION COMPARTMENT
See figure 7. Steps:
1. Loosen the two Phillips screws A and B that secure
the front cover plate two turns.
2. Slide the front cover plate from the cabinet (C)
(downwards).
3. The terminals and cable glands are now accessible.
Note: If necessary you can also remove the gland plate
by loosening screws D, E and F. Read section 4.13
carefully to close the connection compartment
again.
Always close the connection compartment prior to
commissioning of the Mass Systemswitch.
4.6 WIRE CROSS SECTION
For a safe installation the correct wire cross section must
be applied. Don’t use a cross section that is smaller than
indicated. See table below to select the appropriate cross
section for the AC wiring:
AC-Current
Minimum cross section:
in mm²
AWG
0-16 A
2.5 mm²
AWG 13
16-32 A
4 mm²
AWG 11
32-48 A
6 mm²
AWG 9
48-80 A
10 mm²
AWG 7
WARNING
Use cables with the right wire cross section!
Under-sized wires and/or loose connections can cause
dangerous overheating of the wires and/or terminals.
Therefore use the proper size and tighten all connections
well, in order to limit transition resistance as far as
possible.
TRA
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Mass Systemswitch 16 kW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Mass Systemswitch 16 kW in the language / languages: English as an attachment in your email.

The manual is 1.28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info