785627
3
Zoom out
Zoom in
Previous page
1/20
Next page
ENGLISH
Connections
For correct connection - see drawings “INSTALLATION”.
Use reliable cord end terminals to fix the wires to the
DC-input and output.
See specifications for the recommended wire size.
To minimize any EMC-interference we advise to
connect the negative pole of the supplying battery to
the ground.
Connect a momentary switch between the “switch”-
connection and the DC-output ground if you want to use
the remote switch function and/or the light dimmer
function (see drawing 1B, 2B, 3B).
Alarm contact
The alarm contact, right side connection on the back
(see drawings “DIMENSIONS”), is connected to the
contact. The contact is activated and connected to the
output ground in a normal situation, and will be
deactivated if the input voltage is too low (default 10.0V
or 20.0V), if the input voltage is too high (default 16.0V
or 32.0V), in case of overload or short-circuit. The
contact is also deactivated when the MAGIC is switched
off.
Operation
The converter operates automatically. Under normal
circumstances, there is no need for operation. Despite
its low no-load consumption, the converter should be
disconnected from the supplying battery when it is not in
use to protect the battery from discharging.
Refer to table “SWITCH OPERATION” for explanation of
the remote switch function / dimmer operation.
SWITCH OPERATION
Short
Converter switches off.
Press again to switch
on.
Long
After 1 sec. the output
voltage slowly
decreases to 4V or 8V.
Press again to increase
the voltage
Extended functions
Via the “QRS232 communication port” various settings
can be adjusted in terms of software to your specific
demands (control software and interface not included).
Check the Internet site www.mastervolt.com for
applications. Please mind that this plug is not intended
for connecting any remote panels or a battery
temperature sensor.
Battery charger
Three-stage charge curve: Stage A: BULK, for quick
charging from 0 to 80%, Stage B: ABSORPTION, the
battery is charged from 80 to 100%. Stage C: FLOAT,
battery is maintained in fully charged state.
Guarantee terms
Mastervolt guarantees that this converter was built
according to the legally applicable standards and
stipulations. During production and before delivery all
converters were exhaustively tested and controlled. If
you fail to act in accordance with the regulations,
instructions and stipulations in this user’s manual,
damage can occur and/or the converter will not fulfil the
specifications. This may mean that the guarantee will
become null and void.
The guarantee period is 2 years.
Liability
Mastervolt cannot be held liable for:
Consequential damage resulting from the use of the
converter.
Possible errors in the included manual and the
consequences of these.
Use that is inconsistent with the purpose of the
product
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Magic 12 12-20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Magic 12 12-20 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1.48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info