785585
17
Zoom out
Zoom in
Previous page
1/20
Next page
TECHNICAL DATA
EN / GMDSS Mass Charger Alarm Interface / January 2013 / Copyright © 2013 Mastervolt 17
6.2 TECHNICAL SPECIFICATIONS
Type: Mass Charger Alarm Interface - GMDSS Interface
Model MasterVision C1-enlarged cabinet C2 C3
Article number 70400050 21709150 21709200 21709300
Fits in Battery charger: n/a
(flush mounted panel)
Mass 24/25-2 DNV Mass 12/60-2
Mass 12/80-2
Mass 24/50-2
Mass 24/75,
Mass 24/100
Panel Dimensions
(w x h x d)
180 x 65 x 40 mm
Cut-out: 168 x 53 mm
To be integrated in
the battery charger
To be integrated in
the battery charger
To be integrated in
the battery charger
Dimensions shunt 84 x 44 x 44 mm - M8 84 x 44 x 44 mm - M8 84 x 44 x 44 mm - M8 84 x 44 x 44 mm - M8
Weight 400 gr (excl. shunt)
1000 gr (incl. shunt)
500 gr (excl. shunt);
1100 gr (incl. shunt)
500 gr (excl. shunt);
1100 gr (incl. shunt)
500 gr (excl. shunt);
1100 gr (incl. shunt)
Delivery includes: Interface, shunt, user’s manual
Function of instrument Monitoring of the status of the battery and battery charger (12/24V DC)
Manufacturer Mastervolt, Amsterdam, the Netherlands
Number of battery sets 1
Voltage Measurement 0 – 62.7V DC (0.1V resolution); a 12V or 24V system is detected automatically.
Voltage accuracy ± 0.2V @ 12V, ± 0.4V @ 24V
Current Measurement - 500 … 500 Amp
Current accuracy ± 2A (<45A), ± 4A (>45A)
Readout LCD display and status LED’s for DC voltage alarm, Charger alarm and AC mains alarm
Supply voltage 8-32 V DC
Supply current 110mA(@12V) / 65mA(@24V), Normal operation mode without activated relays
Safe compass distance Standard 1 meter; Steering: 0.3mm
Shunt 500 Amp / 50 mV (included with the delivery)
Alarm contacts Potential-free switch over contacts for DC voltage alarm, Charger alarm and AC mains alarm,
Maximum switching current: 1 Amp
6.3 ORDERING INFORMATION
Part number Description
39019052 Single shunt 500A/50mV*
6801601100 Cable 3x2x0.25 mm² twisted stranded wires (per meter)
6801601200 Cable 4x2x0.25 mm² twisted stranded wires (per meter)
6801601300 Cable 5x2x0.25 mm² twisted stranded wires (per meter)
6502001030 Modular RJ 12/ cross wired communication cable (6 m. / 19 ft.)
6502100100 Modular RJ 12/ cross wired communication cable (10 m. / 33 ft.)
6502100150 Modular RJ 12/ cross wired communication cable (15 m. / 48 ft.)
* These parts are standard included with the delivery of the GMDSS Interface
Mastervolt can offer a wide range of products for your electrical installation, including AGM batteries, GEL batteries, DC
distribution kits, battery switches, battery cables, battery terminals and Mastervision switchboards
See our website www.mastervolt.com for an extensive overview of all our products
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt GMDSS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt GMDSS in the language / languages: English as an attachment in your email.

The manual is 0.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info