785575
2
Zoom out
Zoom in
Previous page
1/24
Next page
2
1 GENERAL INFORMATION
1.1 Use of this manual
Copyright © 2011 Mastervolt. All rights reserved.
Reproduction, transfer, distribution or storage of part or
all of the contents in this document in any form without
the prior written permission of Mastervolt is prohibited.
This manual serves as a guideline for the safe and
effective operation of the Digital AC 1x6A.
Keep this manual at a secure place!
1.2 Guarantee specications
Mastervolt guarantees that this product was built
according to the legally applicable standards and
stipulations. If you fail to act in accordance with the
regulations, instructions and stipulations in this user’s
manual, damage can occur and/or the product will
not full the specications. This may mean that the
guarantee will become null and void.
IMPORTANT: The standard guarantee period is two
years after date of purchase.
1.3 Liability
Mastervolt can accept no liability for:
Consequential damage due to use of the Digital AC
1x6A;
Possible errors in the manuals and their results;
Use that is inconsistent with the purpose of the
product.
CAUTION!
Never remove the identication label.
2 OPERATION
2.1 MasterBus functions
The Digital AC 1x6A operation is entirely MasterBus
based. See www.mastervolt.com for information about
MasterBus and the MasterBus event structure. The
table below shows the relay functions.
Monitoring Description Default Range
State Relay can be switched On (active) or Standby Standby Standby / Active
Control Change the state of the relay Standby Active / Standby
Conguration
General
Language Set the MasterBus Digital AC menu language English See specications
Device name Any name you wish with 12 characters max AC Relay 12 characters max
Event locked Check box for installers to lock event conguration.
Only operable by installers.
Unchecked Unchecked / Checked
Conguration Timing
Min. runtime Check box to enable the function Minimum runtime
for switching the relay.
Unchecked Unchecked / Checked
Min. runtime Minimum runtime setting 15 minutes 1-65535 minutes
Max. runtime Check box to enable the function Maximum runtime
for relay switching the relay.
Unchecked Unchecked / Checked
Max. runtime Maximum runtime setting 480 minutes 1-65535 minutes
Event commands
Activate The Digital AC 1x6A can be switched On (activate)
or Standby.
MPC stop MPC (Maximum Power Control) prevents a power
source from being overloaded. At MPC stop the AC
1x6A disconnects the load.
MPC reduce At the end of MPC reduce the AC 1x6A reconnects
the load.
January 2011 / Digital AC 1x6A / EN
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt Digital AC 1x6A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt Digital AC 1x6A in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 4.48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info