CombiMaster 230V serie
Gebruikers- en installatiehandleiding
8.2 Specificaties lader
Model 12 V/2000 VA - 60
A
24 V/2000 VA - 40
A
12 V/3000 VA - 100
A
24 V/3000 VA - 60
A
Ingangsspanningsbereik 90-280 V: vermogensafname onder 170 V (50% bij 90 V, 100% > 170 V)
Max AC-ingangsstroom 6 A 8 A 10 A 12 A
Max. laadstroom bij Tomg =40 ˚C 60 A 40 A 100 A 60 A
Accutemperatuursensor Ingang aanwezig, sensor meegeleverd
Accutemperatuurcompensatie -30 mV per °C -60 mV per °C -30 mV per °C -60 mV per °C
Spanningssensor Nee
Accutypes Nat (standaard) / AGM / Gel / MLI / Constante spanning / Gebruikerbepaald
Laadkarakteristiek Mastervolt 3-traps+, zie de volgende tabel
Laden van ontladen accu's Ja, verminderde (25%) laadstroom bij lage accuspanning (<9 V/<18 V)
Opmerking: de volgende laadspecificaties zijn gebaseerd op Mastervolt-accu's. De specificaties voor accutypes van een
andere fabrikant kunnen afwijkend zijn. Als u accu's van een andere fabrikant aansluit, zorg er dan voor dat de
aanbevelingen van de fabrikant worden opgevolgd. Afzonderlijke aanpassingen zijn mogelijk als in de
configuratie het accutype 'Gebruikerbepaald' is geselecteerd. Door de gebruiker bepaalde accu's kunnen alleen
worden geconfigureerd met een afstandsbediening in een CZone- of MasterBus-netwerk.
Laadspecificaties
Accutype
Nat (standaard)
GEL
AGM
MLI
Bulkspanning* 14,40 V [28,80 V] 14,40 V [28,80 V] 14,40 V [28,80 V] 14,25/28,50 V
Max. bulktijd 480 min 480 min 480 min 480 min
Min. bulktijd 120 s 120 s 120 s 120 s
Start bulktijd op* 13,25/26,50 V 13,25/26,50 V 13,25/26,50 V 13,25/26,50 V
Terug naar
bulkspanning*
12,80/25,60 V 12,80/25,60 V 12,80/25,60 V 13,25/26,50 V
Bulk retourtijd 30 s 30 s 30 s 240 s
Absorbtiespanning* 14,25/28,50 V 14,25/28,50 V 14,25/28,50 V 14,25/28,50 V
Max. abs.tijd 240 min 240 min 240 min 240 min
Min. abs.tijd 15 min 15 min 15 min 15 min
Retourstroom 6,0%*I max. 6,0%*I max. 6,0%*I max. 6,0%*I max.
Floatspanning* 13,25/26,50 V 13,80/27,60 V 13,80/27,60 V 13,50/27,00 V
* ± 1%
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Mastervolt CombiMaster 12 3000-100A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Mastervolt CombiMaster 12 3000-100A in the language / languages: Dutch as an attachment in your email.

The manual is 4.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info