3. Defrost indicator
4. Memory indicator
5. Water tank full indicator
6. Memory button
7. Humidity up button
8. Humidity down button
9. ON/OFF (power) button
OPERATION
1. Plug the unit into a suitable mains socket (please refer
to the rating label on the backside of the unit to check the
appropriate voltage/frequency).
2. Press ON/OFF button to turn on the unit. When turning
on the unit for the rst time, if press only ON/FF button but
not set the Memory, the compressor will start (provided the
room humidity is higher than 50%).
3. Press the buttons Humidity up and Humidity down to
set the required humidity. The setting range is 40%~80%,
1% will be added or reduced for each press. The set hu-
midity will show on the LED display for 8 seconds, after
that the display will return to show the room humidity. Once
the set humidity is achieved, the compressor stops working
automatically.
Humidity range is 35%~95%, when the room humidity is
less than 35%, the LED display shows “LO”, when the
room humidity is higher than 95%, it shows “ HI”.
4. Press ON/OFF button again to turn off the unit.
5. When unit is turned on for the rst time or immediately
after shutoff, there is 3 minute delay protection for com-
pressor.
DEFROST
Unit is equipped with the Hot Gas Defrost function. After
running for 30 minutes, the coil sensor detects the coil tem-
perature. If the coil temperature is ≤-1°C, the unit switches
to the hot gas defrost mode, and the Defrost indicator is
on. During the defrost process, the compressor and the
fan keep running. It takes 5 minutes to defrost (if the coil
temperature raises up to 10°C, the unit drops out of the
defrost mode automatically).
MEMORY
By pressing Memory button, the memory indicator is on,
and the unit remembers the last settings.
HOUR COUNTER FIG. 5
1. A special hour counter serves to count the operation
time of the machine.
2. 7-digit display counts off the operation time, it goes on
continuously, never gets back to “zero”.
6. DRAINAGE
Please note that in case the water tank is not positioned
appropriately, the water full indicator turns red. When the
water tank is full, the compressor stops, as a protective
measure, the “Water Tank Full” indicator turns red and
buzz.
To remove the water tank, pull it out carefully from the unit,
make sure it does not tilt over.
After empting the water tank, place the water tank into the
dedicated space. Make sure it is positioned properly, only
then the ’water full’ indicator is off and your dehumidier
can start working. (FIG. 6)
CONTINUOUS DRAINAGE
When the dehumidier works in extremely high humidity
levels, the water tank requires more frequent drainage. In
this situation, it may be more convenient to set the unit up
for continuous drainage, according to the following proce-
dures:
Remove the drain knob and rubber plug and retain for
future use.
Connect the drain tube to the water outlet (FIG. 7) and
put the other end into a drain.
7. MAINTENANCE
Always unplug the unit from the mains supply before car-
rying out any maintenance or cleaning of the unit.
CASING CLEANING
Use soft cloth to clean the unit.
Don’t ever use volatile chemicals, gasoline, detergents,
chemically treated clothes, or other cleansing solutions as
they may damage the casing.
FILTER CLEANING (FIG. 8)
Extract the lter from the unit.
Use a vacuum cleaner or tap the lter lightly for easy
cleaning. If the lter is excessively dirty, use warm wa-
ter with a small amount of medium strength detergent.
Make sure the lter is completely dry before installing
it back.
Do not expose the lter to sunlight.
STORAGE
If the unit is not used for an extended period of time, please:
Turn off the unit, unplug it and take away the AC cord.
Empty the water tank completely and dry it.
Cover the unit and store it in a place not exposed to the
direct sunlight.
8. TROUBLE SHOOTING
THE UNIT DOES NOT OPERATE:
Is the unit plugged in?
Is the house electricity on?
Is the room temperature below 5
O
C or above 32
O
C? If
so, then it is out of the working range of the unit.
Make sure the ON/OFF switch is turned on.
Check if the water tank is positioned properly inside the
unit and if it is not full.
Make sure the air inlet and outlet are not obstructed.
THE UNIT SEEMS TO DO NOTHING:
Is the lter dusty, contaminated ?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
THE UNIT SEEMS TO DO LITTLE:
Are too many windows or doors open?
Is there something in the room producing a lot of hu-
midity?
THE UNIT IS TOO NOISY:
Check whether the unit is positioned on a level surface.
THE UNIT IS LEAKING:
Make sure the unit is in appropriate condition.
If you are not using continuous drainage, make sure
the rubber plug (on the bottom of the unit) is in its position.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for master DH 732 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of master DH 732 in the language / languages: All languages as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info