SPECIFICATION
Model AC 14 EHP
Cooling capacity * 3956 W
Heating capacity * 3310 W
Power/Ampere consumption for cooling * 1400 W / 6,2 A
Power/Ampere consumption for heating * 1210 W / 5,4 A
Air volume 560 m3/h
Humidity removal capacity * 2,2 l/h
Recommended room size 80 m
3
Power supply 220-240V, ~50Hz
Compressor rotary
Refrigerant R410A
Fan speed 3
Zegar 24h
Working temperature:
- Cooling: 18 ÷ 32°C
- Heating: 7 ÷ 27°C
Connection tube 3m
Net Weight 42 kg
Dimension
Indoor unit: 482 x 420 x 750 mm
Outdoor unit: 479 x 299 x 480 mm
REMARK:
1.
The data marked with '*' may vary for technical reasons: for greater precision, please refer to the rating label placed at the back of the unit.
2.
Measuring condition for above is: Cooling DB 27 C, WB 19 C, Heating - DB 20 C, WB 12 C
BEFORE USE
! OGÓLNE ŚRODKI OSTROŻNOŚCI
! ONLY USE IN THE UPRIGHT POSITION ON A FLAT
LEVEL SURFACE AND AT LEAST 50cm FROM ANY
OBJECTS (Fig 1 & 4).
! DO NOT PLACE OBJECTS ON THE UNIT OR
RESTRICT AIR INLET / OUTLET (FIG. 2).
! CLOSELY SUPERVISE ANY CHILDREN AND PETS
WHEN UNIT IS IN USE.
! FOR INDOOR USE ONLY.
! SWITCH OFF AND UNPLUG WHEN NOT IN USE.
! DO NOT USE IN HUMID OR WET ENVIRONMENTS
(FIG 3)
! DO NOT PULL THE UNIT ALONG BY THE CORD. DO
NOT PULL THE UNIT ALONG BY THE CORD.
FOR MAXIMUM EFFICIENCY
! Close doors and windows
! ! Keep curtains of blinds closed during the sunniest part of
the day
! Keep filters clean
! Once room has reached the desired conditions, reduce
temperature and ventilation settings
PARTS
Front (Fig. 5)
19. Control panel
20. Cooling air outlet
21. Caster
22. Connection tube
23. Handle
24. Exhaust air outlet
Back (Fig. 6)
25. Filter
26. Cord hanger
27. Power Cord
28. Connection box
29. Handle of the outdoor unit
30. Drain hole for heat pump function
31. Fixing clip
Accessories (Fig. 7)
32. Active carbon filter
33. Bracket for mounting outdoor unit
34. Washer, protection cap for terminal of connection tube
35. Remote controller
36. Spanners
INSTALLATION
This product is an air conditioner. It is fitted with an indoor
mobile unit and an outdoor unit that can be rested on the floor or
wall. The two units are connected to each other by a 3 meters
flexible tube. (Fig. 8, 9)
Installation of the outdoor unit.
1. Firmly screw the bracket to the wall. (Fig. 10)
2. Hang the outdoor unit. (Fig. 11)
Notice!
1. The maximum distance for the outdoor unit to the floor
should be within 1.5 M.
2. To avoid damaging the connection tube, leave the window
ajar.
Disconnecting the indoor & outdoor unit
If you need to disconnect the indoor unit from the outdoor unit (to
place it in a more suitable position), please follow the steps below:
11. Open the tube connection box situated at the back of the
indoor unit. (Fig.12).
B. Fixing clip
12. Disconnect the drain tube.(Fig. 13)
E. Electrical cable
F. Refrigerant tube
G. Drain tube
H. Refrigerant tube
13. Disconnect the electrical cable (Fig.13)
14. Disconnect the refrigerant tubes using the spanners
provided.(fig.13). During this operation, takes extreme care
not to break the refrigerant tubes
15. Open the fixing clip above the tube connection box.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for master AC 14 EHP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of master AC 14 EHP in the language / languages: English, German, Danish, Italian, Polish, Spanish as an attachment in your email.

The manual is 1,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info