home automation modules & components
Connection of the Marmitek X-10 module to the wrong mains
voltage.
Opening of the Marmitek X-10 module's housing (with the
exception of types RFIX and IRIX that may be opened for
installation purposes).
Modification or repair of the Marmitek X-10 module or wiring
or any attempt to do so.
The Marmitek X-10 module becomes defective as a result of
connecting potential to the potential-free connecting wires of
the Marmitek X-10 module.
Defects resulting from rough handling of the Marmitek X-10
module or
Defects caused by using the wrong fuses or bridging fuses.
Limitation of liability
Except in the event of liability arising from the law, Marmitek is
not liable for direct damage, material damage or damage to
persons, including consequential damage.
Marmitek is not liable for any indirect damage, immaterial
damage or consequential damage whatsoever, including but not
limited to loss of revenue, damage caused by interruption to
production, loss of profits, pure pecuniary damage etc.
20
Area of application for XANURA home automation
Marmitek is a home automation system that has been designed
to be used exclusively in the housing sector. The area of
application for Marmitek X-10 modules must therefore remain
restricted to residential buildings and the housing sector. It is
not permitted to use Marmitek X-10 modules in the open air or
in humid environments. The system is exclusively intended for
use under the following environmental conditions:
X-10™ home automation
Power supply 230 Vac, 50 Hz
Minimum ambient temperature 0 °C
Maximum ambient temperature 40 °C (*) (**)
Atmospheric pressure 86 pkA - 106 pkA
Relative air humidity (non-condensing) 30 tot 90%
(*) Marmitek X-10 modules are suitable for use in residential environments at
ambient temperatures normally not exceeding 35 °C, occasionally reaching 40
°C.
(**) The maximum load for dim and switch actuators also depends on the ambient
temperature. Please carefully read the instructions for load reduction of dim and
switch actuators before using the Marmitek X-10 modules. The instructions are
enclosed with the dim and switch actuators.
21
Before starting the installation
Before installing a module, you must make sure that the module
is suitable for the intended application. If in doubt, contact a
qualified installer, specialist or the manufacturer for advice.
Instructions for installation & connection of modules
22
Instructions for installation & connection of modules
General installation and connection instructions
PLEASE NOTE: Disregarding the following instruc tions
can considerably shorten the service life of the
Marmitek X-10 modules and will render the guarantee
void! It is recommended to use a certified installer.
1 Use of modules to be restricted to the housing sector
2 Always disconnect the power before installing modules
3 Install in junction box or distribution box (or box with
comparable properties), covered with a cover plate or
switching device.
4 Make sure the live and neutral connections are correct!
5 One module per junction box/distribution box
6 The temperature of the module in the box used may
increase by a max. of 10 °C.
7 Never cover modules with insulation material
8 Pay attention to the proximity of heat sources
9 Prevent potential-free connecting wires from coming into
contact with live components (insulate live components)
10 Do not use objects or force during installation
11 Tightening torque for screws - max. 0.5 Nm
12 Keep modules accessible for programming and maintenance
!
23
Always switch the power off before installing the module.
If the live and neutral wires are connected to the module in
reverse, 230 V will be released on one of the module's
potential-free connecting wires! Make sure that the live and
neutral wires are connected correctly to ensure your safety
and the safety of others, see Figure 1.
2
4
3
5
PROG.
N
L
DAIX
10
Figure 1.
Connect the live wire (2) to the L side of the Marmitek X-10 module, and the
neutral wire (3) to one of the neutral terminals.
Connect the other neutral terminal (4) of the Marmitek X-10 module to the neutral
of the wall socket.
Connect the dimmed output of the Marmitek X-10 module (5) to the live terminal of
the wall socket.
24
Instructions for installation & connection of modules
Marmitek built-in modules must be installed in a junction box or
distribution box.
Other enclosures comparable to junction boxes and distribution
boxes are permitted as long as they meet the following criteria:
In these enclosures, the Marmitek built-in module and other
built-in components or equipment should not cause a
temperature increase within the enclosure that exceeds 10 °C.
Thermal properties at least equal to those of a junction
box/distribution box.
Flame resistance at least equal to that of a junction
box/distribution box.
Only one Marmitek X-10 module to
be installed per junction
box/distribution box. Besides one
Marmitek X-10 module, no other
heat generating components may
be installed in the same junction
box. The installation of several
Marmitek X-10 modules in a single
junction box can lead to the
Marmitek X-10 modules
malfunctioning or becoming
prematurely defective.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marmitek AFX3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marmitek AFX3 in the language / languages: English, Dutch as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info