494305
5
Zoom out
Zoom in
Previous page
1/28
Next page
ENGLISH
5AD10
TM
My modules will not respond to my controller.
Make sure that the House Code on all Modules and Controllers are set to the same House
Code (A .. P).
My modules will not react to my remote / sensor.
When you use a remote or sensor, you should have at least one TM13 Transceiver or
Marmitek Security Console installed in your house. These components will translate the radio
signals to the Marmitek X-10 signal on the power line. Only one Transceiver should be
installed for all remotes and sensors set to the same House Code.
Am I able to increase the range of my remotes by using more Transceivers?
Yes, you can use more than one TM13 Transceiver in your home when the range of your
remotes is not sufficient. The TM13 is using so called collision detection to prevent signals to
be disturbed when more than one TM13 is transmitting. TM13’s will wait for a quite power
line before transmitting their data. To prevent your Marmitek X-10 System to become slow or
to prevent dimming from becoming less smooth, make sure that the TM13 units are placed as
far away from each other as possible.
USER INSTRUCTIONS AD10 DIN RAIL SWITCH
SWITCH OFF APPROPRIATE MAINS FUSE AND MASTER SWITCH!
(INSTALLATION BY A CERTIFIED INSTALLER)
1. Mount the AD10 using the schematics below.
2. Set the rotary code switches on the front side to the desired address.
Description of the selector switch:
Position 0: Always Off
Position 1: Always On
Position Auto: Control with Marmitek X-10 Controllers and
attached switches possible
Terminal 1 of the switch is designed for toggle switches: the
relay picks up when phase is present and releases when there is
no voltage at the terminal.
Terminal 2 of the switch is designed for pulse contacts. Each
time phase is applied, the relay switches (i.e. from OFF to ON or
vice versa).
Technical data
Supply voltage: 230V +10% -15% 50 Hz
Supply current : < 20 mA capacitive
Switching power: 3600W/230V for resistive (ohm) load
700W/230V for inductive/capacitive load
2000W/230V for light bulbs and halogen lighting
Signal sensitivity: 15 mVpp min 50 mVpp max at 120 kHz
Input impedance: > 180 Ohm (L - N) at 120 kHz
Connection: Connection: Connecting clamps for phase, neutral, switched phase,
switch and momentary switch.
Ambient temperature: - 10° C to + 50° C (operation) - 20° C to + 70° C (storage)
Dimensions: 35x80x70mm
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marmitek AD10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marmitek AD10 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info