TROUBLESHOOTING
ABOUT THE PROTECTION CIRCUIT
This unit is equipped with a protection circuit to protect the
amplifier circuits and speaker system from damage.
At power on
For about 8 seconds after the power is turned on, the protection
circuit is activated, muting the sound to give the amplifier
circuits time to stabilize. Once the amplifier circuits stabilize,
the protection circuit is released, and audio is enabled.
In the event of overcurrent
The protection circuit is activated if current exceeding a certain
level is detected, which can happen if excessive signal flow is
input to the amplifier or if the unit is connected to a speaker
system of less than 4 Ω impedance. The protection circuit is
also activated if a speaker cable shorts.
If excessive ultrabass signals are input
The protection circuit is also activated if ultrabass signals are
input.
If the main-amplifier overheats
The protection circuit is activated if the temperature of the main-
amplifier section rises above a certain level, which can happen
if the amplifier is continuously used with excessive signal flow
being input to it. The protection circuit is also activated when
the specified operating temperature is exceeded, which can
happen if the vents on top of the amplifier are covered or if the
amplifier is installed on a cramped audio rack.
In such cases, “PROTECT” flashes on the display, and the
volume is automatically decreased. After about 8 seconds, the
protection circuit is deactivated. Adjust the volume again.
If the abnormality persists, the unit will automatically shut
itself off, and the OPERATE indicator will flash (twice per
second).
In such a case, turn the unit off then back on again after about
1 minute.
7
In the event of amplifier trouble
The protection circuit is activated, and the power is
automatically shut OFF, if an abnormality is detected in the
power circuit. The same happens if the main fuse inside the
amplifier blows. In such cases, the OPERATE indicator flashes.
(8 times per second)
Turn the unit off then after several minutes turn it on again.
If the display does not light up, and the OPERATE indicator
remains flashing after the unit is turned on again, the unit may
be in failure.
In such a case, disconnect the power cord immediately, and
contact the place of purchase, your nearest Marantz dealer,
our customer service center, or our repair service center.
7
Error messages
When multiple amplifiers are connected by F.C.B.S., the error
messages described in the table below may be displayed on
the display. In such a case, ID number setting or remote cable
connection may be in failure. Check the ID number or remote
cable connection, referring to the table below. For details on
ID number setting, see HOW TO SET ID NUMBERS”, on
page 17.
Indication
Meaning
Measures to be taken
1 ERROR 02
Multiple
amplifiers take ID
No. 2.
Assign different
ID numbers to the
amplifiers.
2 ERROR 03
Multiple
amplifiers take ID
No. 3.
3 ERROR 04
Multiple
amplifiers take ID
No. 4.
4 ERROR 11
The amplifiers
with ID Nos.
2-4 cannot
communicate
with the amplifier
with ID No. 1.
If the amplifier with ID
No. 1 is not on, turn
it ON.
Check that the
remote cable is
properly connected.
5 ERROR 12
The amplifier with
ID No. 1 cannot
communicate
with the
amplifiers with ID
Nos. 2-4.
If multiple amplifiers
take ID No. 1, set ID
numbers properly.
Check that the
remote cable is
properly connected.
PM-KI-PEARL_UN_01_Eng.indd 23PM-KI-PEARL_UN_01_Eng.indd 23 09.7.10 11:14:22 AM09.7.10 11:14:22 AM
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantz PM-KI-PEARL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantz PM-KI-PEARL in the language / languages: English as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Marantz PM-KI-PEARL

Marantz PM-KI-PEARL User Manual - Dutch - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info