742782
30
Zoom out
Zoom in
Previous page
1/58
Next page
8. Initial operation
8.5 Express programming
Test run (only necessary after resetting)
Before carrying out the express programming procedure,
the drive system (with the gate coupled up) must be
driven to the factory default OPEN and CLOSED gate
positions using the (+) and (-) buttons.
• Carry out a test run (MASTER and SLAVE).
Express programming
The basic functions of the operator system are set
during the express programming procedure.
MASTER:
- Gate position GATE OPEN
- Gate position GATE CLOSED
- Remote controls
SLAVE (only for double wing gates):
- Gate position GATE OPEN
- Gate position GATE CLOSED
The programming procedure is a consecutive process.
It is essential that this procedure be carried out.
After express programming has been completed and a
learning run has been carried out to set the automatic
cut-out at the OPEN and CLOSED gate positions, the
operator system is ready for operation.
8.5.1 General notes on express programming
Advice:
When programming the OPEN and
CLOSED gate positions, the reference
point must be passed.
8.5.2 Programming buttons
The controls are programmed using the plus (+),
minus (-) and (P) buttons.
If no buttons are pressed within 120 seconds while in
programming mode, the controls revert to operating
mode.
A corresponding message is displayed.
Reference:
The messages are explained in
Section 10.
i
Advice:
For proper initial operation of the
operator system, the express
programming procedure must be
carried out.
• Carry out the express programming according to the
following procedure.
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible
30 Operating Instructions, Comfort 580 GB (#91636)
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Marantec Control x.51 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Marantec Control x.51 in the language / languages: English as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Marantec Control x.51

Marantec Control x.51 User Manual - German - 58 pages

Marantec Control x.51 User Manual - German - 58 pages

Marantec Control x.51 User Manual - French - 58 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info