Operating Instructions, Comfort 580 GB (#91636) 11
6.1 Mounting conditions
6.1 / 1
Mounting position of motor unit
Attention!
To ensure proper operation,
- the foundation box must be concreted
in place in a foundation block,
- all the specified conditions must be
met,
- all the specified dimensions must be
complied with.
6.1 / 2
The distance between the upper edge of the foundation
box and the lower edge of the gate wing must be at
least 55 mm.
6.2 Installing the foundation box
• Place the foundation box (A) in the prepared opening.
• Position the foundation box (A) in the middle of the
opening. Observe the specified installation conditions.
• Connect the conduit (B) for the control cable to the
foundation box (A).
• Connect the drainage pipe (C) to the foundation
box.
• Seal the joints where the conduit (B) and the drainage
pipe (C) connect to the foundation box (A).
6.2 / 1
• Place the spacer cylinder (D) in the foundation box (A).
6.2 / 2
Clearance between gate wing and ground
Advice:
For greater clearance values, a suitable
fitting must be fixed to the gate.
≤ 100430 - 470
0 - 40
> 55
A
B
C
A
D