8. Connection and Initial Operation of the Accessories
English / Page 65
8.5.2 Signal light connection for automatic timer function
(Control 220, Art.-No. 152 814)
Function:
The signal lights are flashing during power-operation of the operator. If automatic
timer function is activated, the signal lights are flashing additionally during
warning time.
Programming of the automatic timer function
Advice / Tip:
Programming of the automatic timer function is carried out in
level 3, menu 1 and 2.
If automatic timer function is activated, an open door is kept open for the time
period of the OPEN door phase. Then the warning time starts. After warning
time the door is closed automatically.
Detailed wiring
diagram
Signal light relay:
Legend:
D40 Control light SIGNAL LIGHTS
F5 Fuse (max. 4A)
H41 Signal light EXIT (orange)
H43 Signal light ENTRANCE (orange)
K40 Relay SIGNAL LIGHTS
Plug connections:
X4a Relay connection
X4b Relay connection
Fig. 27: Wiring diagram